Mark wrote:

when I had this problem and after spending hours with a dvm and hundreds of
bits of paper diagrams,
I gave up and took it to an electricmotor re-winders, 10sec later and two
swapped wires job done.


My mate did as you suggested, and they swapped over the red wires on A
and Az - sorted.


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|