View Single Post
  #11   Report Post  
Brian S Gray
 
Posts: n/a
Default GE Energy Saving Light Bulbs

On Thu, 4 Sep 2003 22:14:39 +0100, "BillR"
wrote:

Martin wrote:
Hi All,
Just bought a GE Energy saving light bulb intended for an outside
light (bottom of the garden).
On the box it states not suitable for use with timers or photo-cell
circuits. Anyone know why? I'd like to run it from a timer or light
detector thingy and leave it on all night.

Martin.


If the timer or whatever has a neutral connection of it own e.g. those plug
in electronic timers, it will be ok.
If the timer relies on a small current through a conventional bulb e.g the
light switch replacement type, it probably won't work.

It is not sufficient that the timer 'plugs in' to a three pin socket.
(see my earlier posting in this thread) - perhaps some timers, which
may include mine, use only two of the three pins.
PS thanks for the replies to my posting.