Default Freezer problem:- defrost heater stuck on, why might this be?


"Nigel Giddings" wrote in message
...

It's a Hotpoint 8591a, the defrost heater is stuck on 24/7 and the fan
isn't blowing so could it be defrost timer/thermostat, fan or drain
problem?

Any advice appreciated, cheers.


The defrost timer may need a bit of adjustment. The defrost timer should
have either a thumb wheel or a slot for a screwdriver on the front of it,
and turning it slowly anti-clockwise until the compressor starts, maybe all
that is needed. You can identify the timer by the shape of it. Most are a
rectangular shape with one corner cut off ( a bit like this :
http://users.ev1.net/~oschmidt/deftimer.gif ) and they will have at least
four connected wires along one edge.

If you give the cam a turn and the compressor starts, then in a day or two
it fails again, this means that the little motor in the timer has failed or
is failing and the unit will need replaced.