View Single Post
  #4   Report Post  
Posted to alt.home.repair
Colbyt
 
Posts: n/a
Default Few very basic Electrical questions


"Doug Miller" wrote in message
. com...
In article , "Colbyt"
wrote:

4. 20 amp circuits by code require 20 amp devices. There really is no
defined limit to the number of devices. The 15 amp ones will most likely
work fine and be safe but they are not "to code".


Incorrect.

The NEC explicitly permits the use of 15A receptacles on a 20A circuit.
See
Article 210.21(B)(3).

--
Regards,
Doug Miller (alphageek at milmac dot com)



Thanks for the info Doug. All these years I thought I was cheating. I
based my assumption on what I saw done in commercial installs. Some of that
stuff might have pulled 17 amps on startup so I guess that is why they went
with all 20's.


Colbyt