Draytona Flowshare 2
In an earlier contribution to this discussion,
sweetpea wrote:
Hi Guys!
I am new to this forum so please bear with me.....
I have a Drayton Flowshare 2 3 port valve..it is causing me endless
problems by sticking in one position or the other.
The question is....does anybody know if i can replace just the syncro
motor head or is it a drain down and complete swap of valve?
Any help advice would be appreciated.
Regards
You can change just the synchro motor in many actuators. Screwfix do one for
under 8 quid which fits ACL Drayton 672, 679 and 773 actuators. Is your one
of these?
Having said that, that may not be the problem. If the mechanical (wet) part
of the valve is sticking, replacing the actuator - or parts thereof - won't
make any difference. So you need to identify the root cause, and attack
*that*.
--
Cheers,
Roger