If your in the US, you need two 20 amp circuits for all outlets in the
kitchen, which is a minimum. All counter outlets must be GFCI protected. You
will need dedicated circuits for heavy loads like built in microwave,
refrigerator, etc. The garage will need one GFCI protected outlet, as will
any unfinished space in the basement. Any appliance like your treadmill that
would require more than 50% of the capacity of a circuit needs a dedicated
line