Default Baxi Main 30 HE or Greenstar 28i Junior?

On April 21 2006, Ed Sirett wrote:

I have a 3 bed detached with 30yr old CH/HW system and have just got
a price from a local Corgi plumber for a complete new system.

8 rads, 4 with trv's, dual prog timer/roomstat, new gas supply from
garage to porch where I want the boiler and the quote price is £2800
with a Baxi Main 30 HE or £3000 with a Greenstar 28i Junior. This
includes removal of all old pipework, rads, tanks etc.

My Question is which boiler should I go for? No baths taken in this
house, just showers

The Baxi spec seems to show 2 heat exchangers (1 caste iron the other
alloy), the 28i only one? Hot water throughput on the baxi is more
12.1 ltr/min against 11.4 ltr/min Baxi states independent control of
hot water /heating temp, dont know on 28i Baxi is 11.9 to 31kw
output, Junior is 7.2 to 28kw

Any installers help point me in the right direction please


Try the BoilerChoice FAQ below for starters.

I'd be interested to know how it is that you have 4 radiators which
don't need TRVs. i.e. Non bedrooms, not less frequently used rooms,
not subject to large
solar gains, not subject to other sources of heat....


The trv's were all for bedrooms and bathroom rads, downstairs is really
one big long room 13x36ft. First 24ft is a lounge where the thermostat
was going and the rest is the dining area. The dining area does have a
large amount of glass (almost 2 walls worth) but faces north and doesnt
have great solar gains. All windows are double glazed and walls cavity
filled btw.

The other rad was for the hall which on reflection should I suppose have
a trv.

Are you thinking the hall should have the stat and the rest of the down
rads have trv's then?

I did already read all the faq listed but am still unsure what I should
be doing, I really want to do away with the top up tanks and airing
cupboard/hot water tank to make way for a maybe loft converted space
later. I am also replacing the kitchen units and really would like the
old floor standing potterton caste iron boiler out of the way along with
its pipework and controls, thats why the boiler in the front porch.