Thread
:
Bizarre reason for RCD nuisance tripping...
View Single Post
#
5
Posted to uk.d-i-y
Andy Wade
Posts: n/a
Bizarre reason for RCD nuisance tripping...
wrote:
lol, weird! Just goes to prove v-ELCBs are better than RCDs
Ah, you were right all along... ;-)
Actually though, something about the story doesn't quite ring true, &
I'm not sure whether to believe it.
If the bedside lampholder was plastic bodied and/or unearthed, most of
the shock current would be phase-neutral. I'd be surprised if there was
enough earth leakage to trip a (presumably) 30 mA RCD, unless her bed
was rather damp.
If the lampholder was earthed metal, why did the old ELCB not trip?
I suppose that a plastic/unearthed lampholder, replaced with earthed
metal after the re-wiring would explain it though.
--
Andy
Reply With Quote