View Single Post
  #3   Report Post  
Posted to sci.electronics.repair,alt.engineering.electrical
Robbie Mayhem
 
Posts: n/a
Default Omron NT600M does not start properly


"jodleren" wrote in message
oups.com...
Hi all!

I got an Omron NT600M-DT122 to fix.

I starts up now somehow, but I do not get any text on screen. AFAIK I
should get _something_ when the battery has been disconnected, some
kind of optional menu.

The first problem was by some reason a resistor between reset (7705
output) and +5V, then I got some life to the data and address lines.
Next, I wanted it stable, and I have to fix the EPROM socket.

When that was done, it starts up "properly", the Run led is on when
resseting, the battery flashes for a short while, backlight comes on,
then nothing more happens.

Any ideas anyone?

BR
Sonnich

It may be worth checking the contrast pot underneath the rubber protective
flap (front of screen, bottom right IIRC), and adjusting as necessary.

Rob