View Single Post
  #2   Report Post  
Posted to sci.electronics.repair
Scott Lane
 
Posts: n/a
Default NEC DX3000 VCR - slow rewind problem

Sounds like the motor is bad. I have had some good luck spraying a small
amount of cleaner/degreaser into some electric motors. Used to "restore"
spindle motors on early Pioneer CD players that would be slow and never
come up to speed. Good luck. Scott
********
"Franc Zabkar" wrote in message
...
I need help to solve a slow rewind problem in an NEC DX3000 VCR. I've
changed the caps on the capstan motor PCB, and I've replaced the belts
and tyres. I can't feel any excessive drag in the mechanism, only the
light application of brake pads to maintain a minimal tape tension.
The motor voltage is 7.4V which is correct according to the service
manual. Fast forward is OK, but should probably be a little faster.
The idler tyre has plenty of grip - I can feel the resistance of the
servo in play and cue/review modes. It seems that the motor's torque
is too low at the applied voltage. In fact I can easily stall the
motor with light finger pressure. The drive voltage remains at 7.2 -
7.4V when I do this.

I can work around the problem by adding a 3K3 resistor in parallel
with R618. This results in a drive voltage of around 8.0V.

If anyone knows of any other common faults with this machine, I'd like
to give it a full service. TIA.

- Franc Zabkar
--
Please remove one 'i' from my address when replying by email.