View Single Post
  #10   Report Post  
Posted to alt.home.repair
hiebs
 
Posts: n/a
Default Refrigerator Compressor Failure?


www.supco.com
a hard start helps a weak compressor get up to speed where it's
original start parts cant. a 3 in 1 comes with overload, relay,
capacitor. a 2 in 1 comes with relay and capacitor. the 2 in 1 leads go
on the run and start terminals on the compressor, you can leave existing
parts connected. and like I said on a different post with all the wires
not connected to compressor terminals take a meter have meter set to
continuity and have one lead to ground and the other touch to each
compressor terminal one at a time if meter reads on any terminal then
compressor is shorted to ground and is junk.


--
hiebs
------------------------------------------------------------------------
hiebs's Profile: http://www.HomeOutfit.com/member.php?userid=69
View this thread: http://www.HomeOutfit.com/showthread.php?t=66886