"N Cook" wrote in message
...
I'm repairing (in theory) a 3 year old monitor, ie far more recent than my
own, so unfamiliar territory.
It uses an NT6827 on screen data display generator and LM1269NA CRT
controller.
The NT6827 is loading the 5V rail and tripping the protection circuitry.
Should be maximum of 25mA at 5V but putting a dropper in line it is taking
70mA when dropped to 3V.
If I disconnected this IC would the monitor work at a basic level or
default
to zero brightness etc?


If the IC really is purely an on screen data display generator then I can't
see how disabling/removing it would affect anything other than the monitors
ability to display the OSD graphics. Why not try and and see?