On 11 Dec 2005 06:18:25 -0800, "
wrote:

Len: Go to this discussion on Sci.electronics.repair re your problem.

http://groups.google.com/group/sci.e...1677def7a68368

Also, I have the service data on this Chassis if you need something
from it.

Robert McPherson
Louisville, KY

Don't worry about the chassis, don't adjust! The reason for fuse blown
was is the convergence power supply that is blown. It is small board
mounted on the black plastic panel. Held down by 1/4" hex bolts. Get
that convergence power supply fixed. There are two types of this by
the way. One use big black IC on Z shaped heatsink, other one is
small U shaped heatsink. Both have different appoaches to repairing
those two types.