View Single Post
  #154   Report Post  
Posted to alt.engineering.electrical,uk.d-i-y,sci.engr.lighting
TKM
 
Posts: n/a
Default UK question: ES light bulb better than bayonet?


"David Lee" wrote in
message . uk...
Chris Bacon wrote...
The last really nasty belt I received was a static shock when I
foolishly put my hand in a Dyson vacuum cleaner canister to dislodge the
fluff


How did that happen, then?


Basically works like a van der Graaf generator. Dry dust particles build
up a static charge by tribo-electrification and this gets transfered to
the walls of the container. Static charge is always repelled towards the
outside of a container and because the dust-container is made of
insulating plastic it builds up on the inside surface of the cylinder. As
soon as an eathed paw is inserted a path to earth is provided and you are
on the receiving end of a large and painful spark!

Used to have the same problem with a HEPA filtered Nilfisk vacuum cleaner
that I used to clean up contaminated spillages of dry alumina powder from
an air abrasive machining apparatus (precision "sand-blaster" I used for
preparing semiconductor specimens). The static charge on the vacuum pipe
(and hence me) - of opposite polarity to that on the dust - would build up
until whatever was most insulating in the circuit via me to ground broke
down, whereupon I would get a nasty shock - until I made up an earthing
strap for the vacuum cleaner!

David


So, if the Dyson has a transparent case -- can't tell from the pictures --
then there ought to be a nice light show in a dark room as the dust whirls
around.

Terry McGowan