View Single Post
  #1   Report Post  
Posted to sci.electronics.design,rec.crafts.metalworking,sci.engr.joining.welding
Glen Walpert
 
Posts: n/a
Default Tested my TIG inverter bridge under full power

On Sat, 26 Nov 2005 08:19:57 GMT, Ignoramus29530
wrote:


Just wanted to say that after slight snubber circuit modifications
(more below), I was able to test my bridge under full welding power of
199 amps.

http://igor.chudov.com/projects/Home...5-Prototype-3/

I also added a cooling fan to cool the main heatsink with IGBTs, as
well as a heatsink for the big ass diode in the snubber circuit. I
drilled a hole in that second heatsink and tapped it for 3/8-20 NF
thread, and screwed the diode in.

It is cold in my garage, perhaps 35F. Given that, and the fan action,
all parts of the bridge stayed cool, except for the main heatsink,
which became warm. Under full power, the IGBTs are expected to produce
approximately 1.2 kW of heat.

Snubber modifications: I added a little Christmas tree of 150 V rated
varistors (total of 5 now), as well as a small 0.33 uF capacitor
across the DC rail. I also remounted the snubber diode by drilling a
tapping a heatsink that I had, and screwing the diode in.

The test (among many tests at smaller amps) went on for a couple of
minutes, until the breakers blew. Like I said, nothing warmed up (I
checked caps, diode, and varistors).


Congratulations! Was that 199 A into a short or into an arc?