View Single Post
  #3   Report Post  
Posted to sci.electronics.repair
Art
 
Posts: n/a
Default sony KV-27FS100 set dead.

Also inspect all the soldering around the horiz drive and output circuits.
"JANA" wrote in message
...
The answer is YES. But you should also verify if the scan generator output
will be reaching the horizontal output transistor. They may also have been
a
failure in the horizontal driver area as well.

In many instances, if the horizontal output device is blown, there may
also
be problems with the power supply, and support circuits that work with the
horizontal output stage.

--

JANA
_____


"clinton" wrote in
message news sony tv dead with stanby light blinking. I replaced the horizontal
output transistor and turned on set and it shorted the output
transistor at turn on.
could the high voltage transformer also be shorted?