"Christian McArdle" wrote in message . net...

However, the fact that it only happens on the hot washes could indicate a
different problem. For example, most washing machines only hot fill on 60C+
washes. If there was a live-earth fault on the hot fill valve or associated
wiring/circuit board track, then this would blow the RCD every time you did
a 60C wash.



Simple way to test it is to remove the connection from the heater,
both of them, and insulate and secure them. If you dont have the
ability to do it safely dont do it.