1. Doesn't a DPC make a weakness in the wall, or is the material such
that the mortar keys into it for a good bond ?
In theory it is a weakness but this is not usually a concern. You will
find pictures of very long walls without movement joints that have moved
on the dpc over time due to thermal expansion. A dpc would also introduce
a weakness into a freestanding (e.g. boundary) wall.
2. Is it better to use a waterproofed mortar and blue bricks ?
Not usually. You might if it is a garden wall and you really need a dpc
3. When inserting a DPC, is the joint thickness between courses usually
still 10mm, or is it thicker ? I need this for the plans.
Usually still 10mm with modern dpcs
--