leak around base of furnace exhaust pipe
I have a new Goodman GMH95 furnace, installed several months ago.
Recently I've noticed water gathering around the base of the exhaust pipe. I've wiped it away and watched it slowly accumulate around the base, as if it's coming from the coupling of the pipe to the furnace itself (not from some exterior source). The screws holding the coupling to the furnace are rusting, so evidently this has been happening for a while but I just noticed it recently. Any ideas as to why this might be happening? Should I just apply a sealant around the pipe where it joins the coupling? Thanks in advance. |
#2
Posted to alt.home.repair
|
|||
|
|||
leak around base of furnace exhaust pipe
Dave,
Since this furnace was installed several months ago give the installer a call. He needs to come out, look at the problem, and come up with a solution. It's called customer service. Dave M. |
#3
Posted to alt.home.repair
|
|||
|
|||
leak around base of furnace exhaust pipe
On Jan 4, 11:57*am, Dave wrote:
If it's coming out of the exhaust, it's possible that it's flue gas condensate. If that's the case, it's either somewhat corrosive (gas heat) or very corrosive (oil heat). Is your furnace one of those brand new high efficiency units (with commensurately very low exhaust temperatures)? Chimney is on an outside wall of the house? |
#4
Posted to alt.home.repair
|
|||
|
|||
leak around base of furnace exhaust pipe
"Dave" wrote in message ... I have a new Goodman GMH95 furnace, installed several months ago. Recently I've noticed water gathering around the base of the exhaust pipe. I've wiped it away and watched it slowly accumulate around the base, as if it's coming from the coupling of the pipe to the furnace itself (not from some exterior source). The screws holding the coupling to the furnace are rusting, so evidently this has been happening for a while but I just noticed it recently. Any ideas as to why this might be happening? Should I just apply a sealant around the pipe where it joins the coupling? Thanks in advance. This should be an issue for the installer. |
#5
Posted to alt.home.repair
|
|||
|
|||
leak around base of furnace exhaust pipe
Bob F wrote:
"Dave" wrote in message ... I have a new Goodman GMH95 furnace, installed several months ago. Recently I've noticed water gathering around the base of the exhaust pipe. I've wiped it away and watched it slowly accumulate around the base, as if it's coming from the coupling of the pipe to the furnace itself (not from some exterior source). The screws holding the coupling to the furnace are rusting, so evidently this has been happening for a while but I just noticed it recently. Any ideas as to why this might be happening? Should I just apply a sealant around the pipe where it joins the coupling? Thanks in advance. This should be an issue for the installer. Dave; There is a supplied drain with a trap that is intened to drain off the condensate to either the sewage or outdoors. If the drain is not pitched correctly, or the trap is not installed correctly, the condensate [water] will collect at the appliance and damage it eventually. Have the originall installing contractor come out and correct the problem. -- Zyp |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
PVC furnace exhaust freezes | Home Repair | |||
Does high efficiency furnace have to exhaust out of roof? | Home Repair | |||
How hot should the exhaust pipe be? | Home Repair | |||
Sound transmission through furnace exhaust vent | Home Ownership | |||
Are birds in high-eff furnace exhaust common? | Home Repair |