Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT
adapters and go for it? Has anyone tried it? |
#2
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On 5/29/18 10:23 PM, OFWW wrote:
Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? My guess is it would be too flexible because it's so thin. It seems to be getting thinner and thinner, too. Anyone see how thin copper pipe is these days? You can practically put your fingernail through it. -- -MIKE- "Playing is not something I do at night, it's my function in life" --Elvin Jones (1927-2004) -- www.mikedrums.com |
#3
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
OFWW wrote in
: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I have not tried it, but I have seen 1/2" black iron pipe bend as the clamps were tightened. I've also played a lot with EMT on the backyard ice rink, and can tell you the 3/4" EMT is probably as flexible as the 1/2 black iron. It's also a lot cheaper too. Let us know if you try it and it works. Puckdropper -- http://www.puckdroppersplace.us/rec.woodworking A mini archive of some of rec.woodworking's best and worst! |
#4
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Tue, 29 May 2018 22:29:25 -0500, -MIKE-
wrote: On 5/29/18 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? My guess is it would be too flexible because it's so thin. It seems to be getting thinner and thinner, too. Anyone see how thin copper pipe is these days? You can practically put your fingernail through it. Yeah, the so-called water grade is pure crap. Even looking at a roll of it will cause dents and the tubing to get out of round. Shudder my first memories of picking some up at the local box store instead of my normal supply house and getting that by mistake. EMT seems about the same, I suppose because steel is a lot less expensive. I think I'll try a short piece first because of the sliding locking clamp and see what happens when it grips the EMT and if it will cave it in or dent it. |
#5
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wed, 30 May 2018 03:34:13 GMT, Puckdropper
wrote: OFWW wrote in : Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I have not tried it, but I have seen 1/2" black iron pipe bend as the clamps were tightened. I've also played a lot with EMT on the backyard ice rink, and can tell you the 3/4" EMT is probably as flexible as the 1/2 black iron. It's also a lot cheaper too. Let us know if you try it and it works. Puckdropper I think I have some short pieces out in the garage, I'll give it a test to see. But yeah, running conduit shows it as flexible, maybe short pieces will react differently? |
#6
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On 5/29/18 10:44 PM, OFWW wrote:
On Wed, 30 May 2018 03:34:13 GMT, Puckdropper wrote: OFWW wrote in : Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I have not tried it, but I have seen 1/2" black iron pipe bend as the clamps were tightened. I've also played a lot with EMT on the backyard ice rink, and can tell you the 3/4" EMT is probably as flexible as the 1/2 black iron. It's also a lot cheaper too. Let us know if you try it and it works. Puckdropper I think I have some short pieces out in the garage, I'll give it a test to see. But yeah, running conduit shows it as flexible, maybe short pieces will react differently? I had thought about something similar one time. Use short stubs of black pipe with the clamps. Install "T"'s on the threaded ends, then street elbows to EMT or other pipe so the system will extend along both sides of a panel glueup. This should eliminate any pipe bowing, assembly issues aside 8^) -BR |
#7
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On 5/29/18 11:41 PM, OFWW wrote:
On Tue, 29 May 2018 22:29:25 -0500, -MIKE- wrote: On 5/29/18 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? My guess is it would be too flexible because it's so thin. It seems to be getting thinner and thinner, too. Anyone see how thin copper pipe is these days? You can practically put your fingernail through it. Yeah, the so-called water grade is pure crap. Even looking at a roll of it will cause dents and the tubing to get out of round. Shudder my first memories of picking some up at the local box store instead of my normal supply house and getting that by mistake. EMT seems about the same, I suppose because steel is a lot less expensive. I think I'll try a short piece first because of the sliding locking clamp and see what happens when it grips the EMT and if it will cave it in or dent it. I wasn't thinking about the clamps caving in or denting the steel, although that is a possibility. I was thinking about the pipe bowing in the middle like cheap bar clamps do. It would cause the jaw faces to splay out and could cause poor/lost grip on the stuff being clamped. -- -MIKE- "Playing is not something I do at night, it's my function in life" --Elvin Jones (1927-2004) -- www.mikedrums.com |
#8
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On 5/29/2018 8:23 PM, OFWW wrote:
Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? EMT is way to light. I can handily bend 3/4 over my knee without hurting my knee. IMC might be a viable alternative, but I have not really compared strength and price to rigid. Also, I do not know how the OD for each compares. I don't know if your pipe clamps would go on easily or not. Need to wander over to the box store and find out I guess. EMT is likely cheapest at the box store, but for rigid or IMC it might pay to check pricing at your local electrical suppliers. Especially if you are buying half a dozen pieces. |
#9
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
OFWW wrote in
: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? My first thought is that if this worked, we'd all have known about it by now, and everybody would be doing it. Has anyone tried it? Not me, and I don't think it's going to work. Here's why: 1) I think it's *too* light, and is going to flex so much under clamping pressure that the clamp jaws won't even be close to parallel (that is, assuming it doesn't just buckle). EMT is called "thinwall" for a reason: wall thicknesses are 0.042" and 0.049" for 1/2" and 3/4" respectively. The corresponding dimensions for Schedule 40 steel pipe are 0.109" and 0.113". EMT is very easy to bend by hand; bending pipe or rigid conduit requires hydraulics. 2) I may be mistaken, but I don't think you're going to find the kind of adapter you need. Rigid electrical conduit is the same size as water pipe, with the same size threads -- but the only EMT-to-rigid adapters I've ever seen have female threads, probably because rigid has male threads on each end. Sure, you can add a pipe nipple too, but now you're starting to move into Rube Goldberg territory... 3) Even if you can manage to somehow adapt the clamp headstock to the EMT, I very much doubt that the tailstock will grip it tightly enough for clamping, because the tailstocks are sized for pipe and EMT is noticeably smaller: actual outside diameters are 1/2" EMT, 0.706"; 1/2" pipe, 0.840; 3/4" EMT, 0.922; 3/4" pipe, 1.050 -- and 1" EMT (1.163") is 10% larger than 3/4" pipe. 4) If you *do* manage both 2) and 3), I think that once you start tightening the clamps, the gripping mechanism in the tailstock will crush the EMT. Like I said, it's called "thinwall" for a reason. If you decide to try it anyway, though, best of luck, and let us know how it turns out. |
#10
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wednesday, May 30, 2018 at 2:58:19 PM UTC-5, Doug Miller wrote:
4) If you *do* manage both 2) and 3), I think that once you start tightening the clamps, the gripping mechanism in the tailstock will crush the EMT. Like I said, it's called "thinwall" for a reason. I doubt the gripping rings on the tail end of the pipe clamps will grip the EMT. The gripping rings are chromed steel. The EMT is chromed or some kind of gray plating. Its slick. I don't think the rings will grip the slick EMT pipe. So no clamping force. I don't think it will grip enough to even dent the thinwall EMT. It'll just slip. |
#11
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Tue, 29 May 2018 22:29:25 -0500, -MIKE-
wrote: On 5/29/18 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? My guess is it would be too flexible because it's so thin. It seems to be getting thinner and thinner, too. Anyone see how thin copper pipe is these days? You can practically put your fingernail through it. That just depends which grade you buy. L is still L, K is still K and M is still M. L is the "standard good" pipe, and M is the crappy cheap stuff that no self respecting plumber would have used 40 years ago. K is the heavy stuff. Now FITTINGS, I will agree. Used to be K or L weight copper, now much of it appears to be the thickness of M, if that. |
#12
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Tue, 29 May 2018 21:41:38 -0700, OFWW
wrote: On Tue, 29 May 2018 22:29:25 -0500, -MIKE- wrote: On 5/29/18 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? My guess is it would be too flexible because it's so thin. It seems to be getting thinner and thinner, too. Anyone see how thin copper pipe is these days? You can practically put your fingernail through it. Yeah, the so-called water grade is pure crap. Even looking at a roll of it will cause dents and the tubing to get out of round. Shudder my first memories of picking some up at the local box store instead of my normal supply house and getting that by mistake. Roll copper has ALWAYS been soft because it is annealed copper. Hard straight copper is what is "generally" used for water plumbing - M has always been thin. M is now stocked as "standard" at the Borg and other big box centers, L is still available and is "standard" at a good plumbing supply - where the cheaper lighter M is also available. EMT seems about the same, I suppose because steel is a lot less expensive. I think I'll try a short piece first because of the sliding locking clamp and see what happens when it grips the EMT and if it will cave it in or dent it. There are standards - which have not changed. |
#13
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wed, 30 May 2018 19:58:16 -0000 (UTC), Doug Miller
wrote: OFWW wrote in : Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? My first thought is that if this worked, we'd all have known about it by now, and everybody would be doing it. Has anyone tried it? Not me, and I don't think it's going to work. Here's why: 1) I think it's *too* light, and is going to flex so much under clamping pressure that the clamp jaws won't even be close to parallel (that is, assuming it doesn't just buckle). EMT is called "thinwall" for a reason: wall thicknesses are 0.042" and 0.049" for 1/2" and 3/4" respectively. The corresponding dimensions for Schedule 40 steel pipe are 0.109" and 0.113". EMT is very easy to bend by hand; bending pipe or rigid conduit requires hydraulics. 2) I may be mistaken, but I don't think you're going to find the kind of adapter you need. Rigid electrical conduit is the same size as water pipe, with the same size threads -- but the only EMT-to-rigid adapters I've ever seen have female threads, probably because rigid has male threads on each end. Sure, you can add a pipe nipple too, but now you're starting to move into Rube Goldberg territory... 3) Even if you can manage to somehow adapt the clamp headstock to the EMT, I very much doubt that the tailstock will grip it tightly enough for clamping, because the tailstocks are sized for pipe and EMT is noticeably smaller: actual outside diameters are 1/2" EMT, 0.706"; 1/2" pipe, 0.840; 3/4" EMT, 0.922; 3/4" pipe, 1.050 -- and 1" EMT (1.163") is 10% larger than 3/4" pipe. 4) If you *do* manage both 2) and 3), I think that once you start tightening the clamps, the gripping mechanism in the tailstock will crush the EMT. Like I said, it's called "thinwall" for a reason. If you decide to try it anyway, though, best of luck, and let us know how it turns out. If your aim is to make a cheap flexible useless clamp, just go buy a cheap chinese one and save the trouble???? BG |
#14
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wed, 30 May 2018 13:23:47 -0700 (PDT), "
wrote: On Wednesday, May 30, 2018 at 2:58:19 PM UTC-5, Doug Miller wrote: 4) If you *do* manage both 2) and 3), I think that once you start tightening the clamps, the gripping mechanism in the tailstock will crush the EMT. Like I said, it's called "thinwall" for a reason. I doubt the gripping rings on the tail end of the pipe clamps will grip the EMT. The gripping rings are chromed steel. The EMT is chromed or some kind of gray plating. Its slick. I don't think the rings will grip the slick EMT pipe. So no clamping force. I don't think it will grip enough to even dent the thinwall EMT. It'll just slip. EMT is NOT chromed, it is electro-zinc plated. |
#15
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wed, 30 May 2018 19:58:16 -0000 (UTC), Doug Miller
wrote: OFWW wrote in : Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? My first thought is that if this worked, we'd all have known about it by now, and everybody would be doing it. Has anyone tried it? Not me, and I don't think it's going to work. Here's why: 1) I think it's *too* light, and is going to flex so much under clamping pressure that the clamp jaws won't even be close to parallel (that is, assuming it doesn't just buckle). EMT is called "thinwall" for a reason: wall thicknesses are 0.042" and 0.049" for 1/2" and 3/4" respectively. The corresponding dimensions for Schedule 40 steel pipe are 0.109" and 0.113". EMT is very easy to bend by hand; bending pipe or rigid conduit requires hydraulics. Possibly but it is worth a check, many clams aren't high pressure clamps anyhow so depending on use it may not make that big of a difference. BTW, I do have rigid pipe benders for 1/2 & 3/4" in my garage. I used to bend pipe on electrical installations for explosion proof connections. 2) I may be mistaken, but I don't think you're going to find the kind of adapter you need. Rigid electrical conduit is the same size as water pipe, with the same size threads -- but the only EMT-to-rigid adapters I've ever seen have female threads, probably because rigid has male threads on each end. Sure, you can add a pipe nipple too, but now you're starting to move into Rube Goldberg territory... EMT to box connectors, work with rigid nipples as well. They typically will bottom out because they are a straight not a tapered thread but they can be tightened. 3) Even if you can manage to somehow adapt the clamp headstock to the EMT, I very much doubt that the tailstock will grip it tightly enough for clamping, because the tailstocks are sized for pipe and EMT is noticeably smaller: actual outside diameters are 1/2" EMT, 0.706"; 1/2" pipe, 0.840; 3/4" EMT, 0.922; 3/4" pipe, 1.050 -- and 1" EMT (1.163") is 10% larger than 3/4" pipe. Last I checked the OD of 3/4 pipe was smaller than EMT. and yes the tail stock would be the first thing to check out since if it did fit will it hold without damage the conduit. 4) If you *do* manage both 2) and 3), I think that once you start tightening the clamps, the gripping mechanism in the tailstock will crush the EMT. Like I said, it's called "thinwall" for a reason. If you decide to try it anyway, though, best of luck, and let us know how it turns out. I hope to give it a go this week sometime. It is just a question that nagged me for years. Thanks for your thoughts. |
#16
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wed, 30 May 2018 17:32:00 -0400, Clare Snyder
wrote: On Wed, 30 May 2018 19:58:16 -0000 (UTC), Doug Miller wrote: OFWW wrote in m: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? My first thought is that if this worked, we'd all have known about it by now, and everybody would be doing it. Has anyone tried it? Not me, and I don't think it's going to work. Here's why: 1) I think it's *too* light, and is going to flex so much under clamping pressure that the clamp jaws won't even be close to parallel (that is, assuming it doesn't just buckle). EMT is called "thinwall" for a reason: wall thicknesses are 0.042" and 0.049" for 1/2" and 3/4" respectively. The corresponding dimensions for Schedule 40 steel pipe are 0.109" and 0.113". EMT is very easy to bend by hand; bending pipe or rigid conduit requires hydraulics. 2) I may be mistaken, but I don't think you're going to find the kind of adapter you need. Rigid electrical conduit is the same size as water pipe, with the same size threads -- but the only EMT-to-rigid adapters I've ever seen have female threads, probably because rigid has male threads on each end. Sure, you can add a pipe nipple too, but now you're starting to move into Rube Goldberg territory... 3) Even if you can manage to somehow adapt the clamp headstock to the EMT, I very much doubt that the tailstock will grip it tightly enough for clamping, because the tailstocks are sized for pipe and EMT is noticeably smaller: actual outside diameters are 1/2" EMT, 0.706"; 1/2" pipe, 0.840; 3/4" EMT, 0.922; 3/4" pipe, 1.050 -- and 1" EMT (1.163") is 10% larger than 3/4" pipe. 4) If you *do* manage both 2) and 3), I think that once you start tightening the clamps, the gripping mechanism in the tailstock will crush the EMT. Like I said, it's called "thinwall" for a reason. If you decide to try it anyway, though, best of luck, and let us know how it turns out. If your aim is to make a cheap flexible useless clamp, just go buy a cheap chinese one and save the trouble???? BG LOL, I have American made newer F clamps that are mighty weak. It is surprising that many don't publish the max clamping ft/lbs. |
#17
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wed, 30 May 2018 09:49:46 -0500, -MIKE-
wrote: On 5/29/18 11:41 PM, OFWW wrote: On Tue, 29 May 2018 22:29:25 -0500, -MIKE- wrote: On 5/29/18 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? My guess is it would be too flexible because it's so thin. It seems to be getting thinner and thinner, too. Anyone see how thin copper pipe is these days? You can practically put your fingernail through it. Yeah, the so-called water grade is pure crap. Even looking at a roll of it will cause dents and the tubing to get out of round. Shudder my first memories of picking some up at the local box store instead of my normal supply house and getting that by mistake. EMT seems about the same, I suppose because steel is a lot less expensive. I think I'll try a short piece first because of the sliding locking clamp and see what happens when it grips the EMT and if it will cave it in or dent it. I wasn't thinking about the clamps caving in or denting the steel, although that is a possibility. I was thinking about the pipe bowing in the middle like cheap bar clamps do. It would cause the jaw faces to splay out and could cause poor/lost grip on the stuff being clamped. I've had that problem with any pipe clamps. I threw them all away and bought Besseys. No problems with them. |
#18
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wed, 30 May 2018 17:28:41 -0400, Clare Snyder
wrote: On Tue, 29 May 2018 21:41:38 -0700, OFWW wrote: On Tue, 29 May 2018 22:29:25 -0500, -MIKE- wrote: On 5/29/18 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? My guess is it would be too flexible because it's so thin. It seems to be getting thinner and thinner, too. Anyone see how thin copper pipe is these days? You can practically put your fingernail through it. Yeah, the so-called water grade is pure crap. Even looking at a roll of it will cause dents and the tubing to get out of round. Shudder my first memories of picking some up at the local box store instead of my normal supply house and getting that by mistake. Roll copper has ALWAYS been soft because it is annealed copper. Hard straight copper is what is "generally" used for water plumbing - M has always been thin. M is now stocked as "standard" at the Borg and other big box centers, L is still available and is "standard" at a good plumbing supply - where the cheaper lighter M is also available. 'L' copper is available at the BORG, too. It costs about 50% more than type 'M' but it is available. I use it for compressed air. EMT seems about the same, I suppose because steel is a lot less expensive. I think I'll try a short piece first because of the sliding locking clamp and see what happens when it grips the EMT and if it will cave it in or dent it. There are standards - which have not changed. Like the size of a 2x4? ;-) |
#19
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wed, 30 May 2018 19:10:52 -0700, OFWW
wrote: On Wed, 30 May 2018 17:32:00 -0400, Clare Snyder wrote: On Wed, 30 May 2018 19:58:16 -0000 (UTC), Doug Miller wrote: OFWW wrote in : Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? My first thought is that if this worked, we'd all have known about it by now, and everybody would be doing it. Has anyone tried it? Not me, and I don't think it's going to work. Here's why: 1) I think it's *too* light, and is going to flex so much under clamping pressure that the clamp jaws won't even be close to parallel (that is, assuming it doesn't just buckle). EMT is called "thinwall" for a reason: wall thicknesses are 0.042" and 0.049" for 1/2" and 3/4" respectively. The corresponding dimensions for Schedule 40 steel pipe are 0.109" and 0.113". EMT is very easy to bend by hand; bending pipe or rigid conduit requires hydraulics. 2) I may be mistaken, but I don't think you're going to find the kind of adapter you need. Rigid electrical conduit is the same size as water pipe, with the same size threads -- but the only EMT-to-rigid adapters I've ever seen have female threads, probably because rigid has male threads on each end. Sure, you can add a pipe nipple too, but now you're starting to move into Rube Goldberg territory... 3) Even if you can manage to somehow adapt the clamp headstock to the EMT, I very much doubt that the tailstock will grip it tightly enough for clamping, because the tailstocks are sized for pipe and EMT is noticeably smaller: actual outside diameters are 1/2" EMT, 0.706"; 1/2" pipe, 0.840; 3/4" EMT, 0.922; 3/4" pipe, 1.050 -- and 1" EMT (1.163") is 10% larger than 3/4" pipe. 4) If you *do* manage both 2) and 3), I think that once you start tightening the clamps, the gripping mechanism in the tailstock will crush the EMT. Like I said, it's called "thinwall" for a reason. If you decide to try it anyway, though, best of luck, and let us know how it turns out. If your aim is to make a cheap flexible useless clamp, just go buy a cheap chinese one and save the trouble???? BG LOL, I have American made newer F clamps that are mighty weak. It is surprising that many don't publish the max clamping ft/lbs. Yes, and "american made" really doesn't mean anything anymore - "made in the USA of world sourced parts" just means they put in the last rivet or pin and put it in a box. |
#20
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On 5/29/2018 10:23 PM, OFWW wrote:
Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I'm sure this is obvious,,,,, what is EMT? Emergency Medical Team? ;~) |
#21
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
Leon lcb11211@swbelldotnet writes:
On 5/29/2018 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I'm sure this is obvious,,,,, what is EMT? Emergency Medical Team? ;~) Electro-metallic tubing. |
#22
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On 5/31/2018 1:04 PM, Scott Lurndal wrote:
Leon lcb11211@swbelldotnet writes: On 5/29/2018 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I'm sure this is obvious,,,,, what is EMT? Emergency Medical Team? ;~) Electro-metallic tubing. Thank you Scott. Is that like the electrical conduit? If so, certainly not stiff enough to prevent the glued up from bowing. |
#23
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
Leon lcb11211@swbelldotnet writes: On 5/31/2018 1:04 PM, Scott Lurndal wrote: Leon lcb11211@swbelldotnet writes: On 5/29/2018 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I'm sure this is obvious,,,,, what is EMT? Emergency Medical Team? ;~) Electro-metallic tubing. Thank you Scott. Is that like the electrical conduit? If so, certainly not stiff enough to prevent the glued up from bowing. It is exactly electrical conduit, and there is no way it would work for clamping. Flexible Metal Conduit (FMC), EMT, Galvy rigid (GRC), Intermediate Metal (IMC), Rigid Metal/Steel (RMC/RSC) and Rigid non-metallic (PVC). |
#24
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On 5/31/2018 1:14 PM, Leon wrote:
.... Is that like the electrical conduit?Â* If so, certainly not stiff enough to prevent the glued up from bowing. Precisely...it's a nonsense thread from the git-go. Nominal OD Sch 40 EMT OD 1/2" 0.840" 0.706" 3/4" 1.05" 0.922 so the EMT is almost a full 1/8" smaller diameter so clamps wouldn't clamp even if the wall thickness weren't such that would simply collapse it if did. -- |
#25
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Wednesday, May 30, 2018 at 4:32:43 PM UTC-5, Clare Snyder wrote:
On Wed, 30 May 2018 13:23:47 -0700 (PDT), " wrote: I doubt the gripping rings on the tail end of the pipe clamps will grip the EMT. The gripping rings are chromed steel. The EMT is chromed or some kind of gray plating. Its slick. I don't think the rings will grip the slick EMT pipe. So no clamping force. I don't think it will grip enough to even dent the thinwall EMT. It'll just slip. EMT is NOT chromed, it is electro-zinc plated. OK. But my point is still valid. I don't think the grip rings will work on the electro zinc plated coating. Too slippery. |
#26
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Thu, 31 May 2018 14:05:29 -0700 (PDT), "
wrote: On Wednesday, May 30, 2018 at 4:32:43 PM UTC-5, Clare Snyder wrote: On Wed, 30 May 2018 13:23:47 -0700 (PDT), " wrote: I doubt the gripping rings on the tail end of the pipe clamps will grip the EMT. The gripping rings are chromed steel. The EMT is chromed or some kind of gray plating. Its slick. I don't think the rings will grip the slick EMT pipe. So no clamping force. I don't think it will grip enough to even dent the thinwall EMT. It'll just slip. EMT is NOT chromed, it is electro-zinc plated. OK. But my point is still valid. I don't think the grip rings will work on the electro zinc plated coating. Too slippery. They work fine on clamps that come with electrozinc plated "pipes" from the factory. If the tube is the right size they will hold - but EMT is not the same size as pipe, and is too flimsy -0 the grip plates will deform the tube. |
#27
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Thu, 31 May 2018 13:01:05 -0500, Leon lcb11211@swbelldotnet
wrote: On 5/29/2018 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I'm sure this is obvious,,,,, what is EMT? Emergency Medical Team? ;~) Electro Metalic Tubing - AKA lightweight electrical conduit. |
#28
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
Clare Snyder wrote in news:edt0hdl19fdiu4rioi9n8lha0qslbrdj7k@
4ax.com: On Thu, 31 May 2018 14:05:29 -0700 (PDT), " wrote: On Wednesday, May 30, 2018 at 4:32:43 PM UTC-5, Clare Snyder wrote: On Wed, 30 May 2018 13:23:47 -0700 (PDT), " wrote: I doubt the gripping rings on the tail end of the pipe clamps will grip the EMT. The gripping rings are chromed steel. The EMT is chromed or some kind of gray plating. Its slick. I don't think the rings will grip the slick EMT pipe. So no clamping force. I don't think it will grip enough to even dent the thinwall EMT. It'll just slip. EMT is NOT chromed, it is electro-zinc plated. OK. But my point is still valid. I don't think the grip rings will work on the electro zinc plated coating. Too slippery. They work fine on clamps that come with electrozinc plated "pipes" from the factory. Perhaps for some definitions of "just fine'. I haven't had good experiences using pipe clamps with galvanized pipe. |
#29
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
OFWW wrote in
: On Wed, 30 May 2018 19:58:16 -0000 (UTC), Doug Miller wrote: 3) Even if you can manage to somehow adapt the clamp headstock to the EMT, I very much doubt that the tailstock will grip it tightly enough for clamping, because the tailstocks are sized for pipe and EMT is noticeably smaller: actual outside diameters are 1/2" EMT, 0.706"; 1/2" pipe, 0.840; 3/4" EMT, 0.922; 3/4" pipe, 1.050 -- and 1" EMT (1.163") is 10% larger than 3/4" pipe. Last I checked the OD of 3/4 pipe was smaller than EMT. It's the other way around -- I even listed the diameters above. The actual outside diameter of steel pipe is greater than the actual outside diameter of EMT of the same nominal size, in all cases. |
#30
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
Leon lcb11211@swbelldotnet wrote in news:LNWdnWswz5r1pY3GnZ2dnUU7-
: On 5/29/2018 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I'm sure this is obvious,,,,, what is EMT? Emergency Medical Team? ;~) Electrical Metallic Tubing aka "thinwall conduit". Very different stuff from RMC (Rigid Metal Conduit) which is similar in weight, size, and stiffness to water pipe. |
#31
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On 6/1/2018 10:21 AM, Doug Miller wrote:
Leon lcb11211@swbelldotnet wrote in news:LNWdnWswz5r1pY3GnZ2dnUU7- : On 5/29/2018 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? Has anyone tried it? I'm sure this is obvious,,,,, what is EMT? Emergency Medical Team? ;~) Electrical Metallic Tubing aka "thinwall conduit". Very different stuff from RMC (Rigid Metal Conduit) which is similar in weight, size, and stiffness to water pipe. Thank you Doug. |
#32
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Tue, 29 May 2018 20:23:06 -0700
OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? depends are you a clamp it hard to deal with any errors or other imperfections in wood or cuts or what have you or are you a clamp it just to keep it together until cured |
#33
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Fri, 1 Jun 2018 13:42:01 -0000 (UTC), Doug Miller
wrote: OFWW wrote in : On Wed, 30 May 2018 19:58:16 -0000 (UTC), Doug Miller wrote: 3) Even if you can manage to somehow adapt the clamp headstock to the EMT, I very much doubt that the tailstock will grip it tightly enough for clamping, because the tailstocks are sized for pipe and EMT is noticeably smaller: actual outside diameters are 1/2" EMT, 0.706"; 1/2" pipe, 0.840; 3/4" EMT, 0.922; 3/4" pipe, 1.050 -- and 1" EMT (1.163") is 10% larger than 3/4" pipe. Last I checked the OD of 3/4 pipe was smaller than EMT. It's the other way around -- I even listed the diameters above. The actual outside diameter of steel pipe is greater than the actual outside diameter of EMT of the same nominal size, in all cases. Actually that is sort of what I figured based on the tools for each that I have, but I was going by the info on the HD site last week which seemed strange to me, but,,,,? Anyhow, I tried it today, it was a no show. The emt is small enough that the tail stock would not grip it tightly. Given the nature of the design I thought it might come close, but it was a no show. |
#34
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Fri, 1 Jun 2018 10:18:11 -0700, Electric Comet
wrote: On Tue, 29 May 2018 20:23:06 -0700 OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT adapters and go for it? depends are you a clamp it hard to deal with any errors or other imperfections in wood or cuts or what have you or are you a clamp it just to keep it together until cured One grips it so there is consistency down the full length of the joint, tightly. No room for imperfections, etc. Glue is not a filler. |
#35
Posted to rec.woodworking
|
|||
|
|||
Has anyone tried using EMT with pipe clamps?
On Thursday, May 31, 2018 at 11:14:53 AM UTC-7, Leon wrote:
On 5/31/2018 1:04 PM, Scott Lurndal wrote: Leon lcb11211@swbelldotnet writes: On 5/29/2018 10:23 PM, OFWW wrote: Was just thinking, EMT is so much lighter, so why nor use Pipe to EMT I'm sure this is obvious,,,,, what is EMT? Emergency Medical Team? ;~) Electro-metallic tubing. Is that like the electrical conduit? If so, certainly not stiff enough to prevent the glued up from bowing. Exactly. Both EMT (thin stuff) and conduit (thicker, can tolerate wet) are bending-grade tubing. Black iron pipe is not. Black iron is thrifty compared with structural steel, but not a lot weaker. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Anyone tried using a hot glue gun to bind books? | UK diy | |||
Has anyone tried using one of these? | Metalworking | |||
Has anyone tried the mop shoe? | Home Ownership | |||
FS : Pipe Clamps & Deep throat Pipe clamps | Woodworking | |||
Has anyone Tried to Recycle heat from Dryer vent? | Home Repair |