Dale August 12th 03 04:49 AM

Question about remote for dust collector
 
Right now I'm in the stage of researching the components for a dust
collection system for my small shop. I think I've decided on the Penn
State DC-2 1 1/2 HP collector with 1 micron bags which is on sale
right now for $249 plus $44 shipping. I'm going to add a garbage can
cyclone unit. The DC will be used with only one tool running at a
time. I've got separate 20 Amp circuits for my tools-table saw,
thickness planer, miter saw, jointer, etc. and a dedicated 15 amp
circuit for my DC. I was hoping to have a 20 amp dedicated for the DC
but because of some existing 14 AWG wire that would be very difficult
to upgrade I'm stuck with 15. I have two questions for you
electrically adept people. Question 1- The Penn State catalog lists
the "capacity" of the DC-2 at 17 amps but then says that running
amperage will be significantly less. Am I going to have problems with
breakers tripping by running this on my 15 amp circuit? Question 2-
I'm looking at running the DC on some kind of remote and Home Depot in
my area has a Heath/Zenith Indoor/Outdoor remote light control, model
#SL-6139-C that is listed for 13 amp resistive according to the
package. Will this unit be able to handle the DC-2 or is this a
hazardous situation? Thanks for any help you can provide.

Dale

Edwin Pawlowski August 12th 03 12:13 PM

Question about remote for dust collector
 

"Dale" wrote in message

to upgrade I'm stuck with 15. I have two questions for you
electrically adept people. Question 1- The Penn State catalog lists
the "capacity" of the DC-2 at 17 amps but then says that running
amperage will be significantly less. Am I going to have problems with
breakers tripping by running this on my 15 amp circuit?


Mine is on a 15A, never a problem.


Question 2-
I'm looking at running the DC on some kind of remote and Home Depot in
my area has a Heath/Zenith Indoor/Outdoor remote light control, model
#SL-6139-C that is listed for 13 amp resistive according to the
package. Will this unit be able to handle the DC-2 or is this a
hazardous situation? Thanks for any help you can provide.


I have no idea, but it was designed for lighting, may not handle a motor
load well. . I do have the Long Ranger and it works just fine. Very handy
to have. It was about $50
Ed

http://pages.cthome.net/edhome




Orlun August 12th 03 12:53 PM

Question about remote for dust collector
 
I have no idea, but it was designed for lighting, may not handle a motor
load well. . I do have the Long Ranger and it works just fine. Very

handy
to have. It was about $50
Ed


My Dust collector runs fine on my 15amp garage circuit. I also use the
Long Ranger remote for controlling it. Works great and am very pleased with
it.



MGH August 12th 03 01:38 PM

Question about remote for dust collector
 


I'm looking at running the DC on some kind of remote and Home Depot in
my area has a Heath/Zenith Indoor/Outdoor remote light control, model
#SL-6139-C that is listed for 13 amp resistive according to the
package. Will this unit be able to handle the DC-2 or is this a
hazardous situation? Thanks for any help you can provide.

Dale


My DC, a home built cyclone unit is on a 15 amp circuit but draws I think 11
amp. I have been using the Heath/Zenith Indoor/Outdoor remote for the past
two months, works great and for only $12.

MGH



PC August 12th 03 01:46 PM

Question about remote for dust collector
 
I'd be concerned about the life time of the Heath/Zenith unit switching
an inductive load like the motor. I believe that they make other units
rated for switch inductive loads though. Resistive loads are less
taxing on the switch since they don't have the same tendency to arc.

Phil

Edwin Pawlowski wrote:
"Dale" wrote in message


to upgrade I'm stuck with 15. I have two questions for you
electrically adept people. Question 1- The Penn State catalog lists
the "capacity" of the DC-2 at 17 amps but then says that running
amperage will be significantly less. Am I going to have problems with
breakers tripping by running this on my 15 amp circuit?



Mine is on a 15A, never a problem.


Question 2-

I'm looking at running the DC on some kind of remote and Home Depot in
my area has a Heath/Zenith Indoor/Outdoor remote light control, model
#SL-6139-C that is listed for 13 amp resistive according to the
package. Will this unit be able to handle the DC-2 or is this a
hazardous situation? Thanks for any help you can provide.



I have no idea, but it was designed for lighting, may not handle a motor
load well. . I do have the Long Ranger and it works just fine. Very handy
to have. It was about $50
Ed

http://pages.cthome.net/edhome





Chris Merrill August 12th 03 01:51 PM

Question about remote for dust collector
 
Dale wrote:
I'm looking at running the DC on some kind of remote and Home Depot in
my area has a Heath/Zenith Indoor/Outdoor remote light control, model
#SL-6139-C that is listed for 13 amp resistive according to the
package. Will this unit be able to handle the DC-2 or is this a
hazardous situation? Thanks for any help you can provide.


The Ace Hardware in my area has a remote unit that is rated for
1 1/2hp motors...for $25, IIRC.

--
************************************
Chris Merrill

(remove the ZZZ to contact me)
************************************


B a r r y B u r k e J r . August 13th 03 11:51 AM

Question about remote for dust collector
 
On Tue, 12 Aug 2003 23:50:49 GMT, Bob G wrote:


I also took two 3 way switches and and placed them along the center of
my 24 x 24 foot shop and 6 foot out from the walls on both ends Since
I have a low ceiling I can reach up and use either ..and I am never more
then 2 steps away from the switches no matter where I stand in the


It sounds like we had a little synchronicity going on when we wired
our dust collectors. G

Mine is exactly the same setup, as I'm in a basement. The switches
are on the center beam of the house.

Barry


Oughtsix August 14th 03 09:42 AM

Question about remote for dust collector
 
Go to ebay and search for a NEMA size 0 or bigger contactor, two or
three phase contactors will work just fine. ($20 absolute max even if
you don't know how to find a bargain on ebay)
Since you are running on 110v make sure to get a contactor with a 110v
coil. Wire a plug onto the coil of the contactor and plug it into the
Heath/Zenith remote. Wire another plug onto two of the poles on the
contactor and a recepticle onto the other side of the two poles on the
contactor.

The remote will be able to handle any load you throw at it, Dust
collector, fan, stereo, heater all put together (14g wire won't
though).

ie. a contactor is just a fancy name for a relay made to handle large
amounts of current.

On 11 Aug 2003 20:49:19 -0700, (Dale)
wrote:

Right now I'm in the stage of researching the components for a dust
collection system for my small shop. I think I've decided on the Penn
State DC-2 1 1/2 HP collector with 1 micron bags which is on sale
right now for $249 plus $44 shipping. I'm going to add a garbage can
cyclone unit. The DC will be used with only one tool running at a
time. I've got separate 20 Amp circuits for my tools-table saw,
thickness planer, miter saw, jointer, etc. and a dedicated 15 amp
circuit for my DC. I was hoping to have a 20 amp dedicated for the DC
but because of some existing 14 AWG wire that would be very difficult
to upgrade I'm stuck with 15. I have two questions for you
electrically adept people. Question 1- The Penn State catalog lists
the "capacity" of the DC-2 at 17 amps but then says that running
amperage will be significantly less. Am I going to have problems with
breakers tripping by running this on my 15 amp circuit? Question 2-
I'm looking at running the DC on some kind of remote and Home Depot in
my area has a Heath/Zenith Indoor/Outdoor remote light control, model
#SL-6139-C that is listed for 13 amp resistive according to the
package. Will this unit be able to handle the DC-2 or is this a
hazardous situation? Thanks for any help you can provide.

Dale