heating system
I am looking at how to design a heating system and there are a few
things that I need help on. If I have the heat loss from a room(W) the desired temperature of the room(c) how would I get from those figures back to a flow/return temperature in the radiator? I know that the rads are designed on a 50 degree temp difference between the ambient air and the mean water temp in the rad, and that mean water temp is made up from the flow/return temps but if I was looking at the design of the initial heat source would I just design for an approximate heat output and then size the rad around this output or are there some definite calcs that can be done. Any help appreciated Cheers |
#2
|
|||
|
|||
"paulend" wrote in message oups.com... I am looking at how to design a heating system and there are a few things that I need help on. If I have the heat loss from a room(W) the desired temperature of the room(c) how would I get from those figures back to a flow/return temperature in the radiator? I know that the rads are designed on a 50 degree temp difference between the ambient air and the mean water temp in the rad, and that mean water temp is made up from the flow/return temps but if I was looking at the design of the initial heat source would I just design for an approximate heat output and then size the rad around this output or are there some definite calcs that can be done. Any help appreciated There is a thread at the mo' about a heat calcs. That is you first step. What sort of DHW do you want? mains pressure? Other? _________________________________________ Usenet Zone Free Binaries Usenet Server More than 120,000 groups Unlimited download http://www.usenetzone.com to open account |
#3
|
|||
|
|||
could you give me the link to the other thread? There is no DHW
needed, it is purely space heating Cheers |
#4
|
|||
|
|||
"paulend" wrote in message oups.com... could you give me the link to the other thread? There is no DHW needed, it is purely space heating Cheers long thin "radiator" _________________________________________ Usenet Zone Free Binaries Usenet Server More than 120,000 groups Unlimited download http://www.usenetzone.com to open account |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Heating system - how much space needed? | UK diy | |||
Not all radiators emptying when draining central heating system | UK diy | |||
remote control of a central heating system - possible? | UK diy | |||
Pool water in central heating system | UK diy | |||
Underfloor heating | UK diy |