JK May 30th 04 12:52 PM

ground floor chimney breast partial removal
 
I've read with some alarm old posts in the group about removing the chimney
breast from downstairs rooms. I don't really fancy the expense of getting
it completely removed and properly supported. But is there a way of simply
opening it up to somewhere near ceiling height, leaving a pillar of bricks
on either side and supporting with an RSJ across those pillars. So it would
be like a normal fireplace, only a lot bigger, creating an alcove of usable
space. This is in a ground floor flat, no access to the upstairs at all
(though cooperative people upstairs who would allow anything that was
complying with regs and done by professionals).

Thanks,

John



BigWallop May 30th 04 03:03 PM

ground floor chimney breast partial removal
 
JK wrote:
I've read with some alarm old posts in the group about removing the chimney
breast from downstairs rooms. I don't really fancy the expense of getting
it completely removed and properly supported. But is there a way of simply
opening it up to somewhere near ceiling height, leaving a pillar of bricks
on either side and supporting with an RSJ across those pillars. So it would
be like a normal fireplace, only a lot bigger, creating an alcove of usable
space. This is in a ground floor flat, no access to the upstairs at all
(though cooperative people upstairs who would allow anything that was
complying with regs and done by professionals).

Thanks,

John


There is no way to remove only a partial section of a chimney breast because it
is most commonly forming an actual part of the building structural support. The
only way is to remove all or none I'm afraid.


---
http://www.basecuritysystems.no-ip.com

Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.692 / Virus Database: 453 - Release Date: 28/05/04



JK June 1st 04 09:04 AM

ground floor chimney breast partial removal
 
BigWallop wrote:
JK wrote:
I've read with some alarm old posts in the group about removing the
chimney breast from downstairs rooms. I don't really fancy the
expense of getting it completely removed and properly supported. But
is there a way of simply opening it up to somewhere near ceiling
height, leaving a pillar of bricks on either side and supporting
with an RSJ across those pillars. So it would be like a normal
fireplace, only a lot bigger, creating an alcove of usable space.
This is in a ground floor flat, no access to the upstairs at all
(though cooperative people upstairs who would allow anything that
was complying with regs and done by professionals).

Thanks,

John


There is no way to remove only a partial section of a chimney breast
because it is most commonly forming an actual part of the building
structural support. The only way is to remove all or none I'm afraid.


But all I'm proposing is something like a larger fireplace opening. As it
was built, it would have have an opening about 3' square with a lintel for
support. I'm just thinking I could make that higher and a bit wider, with a
bigger lintel.



BigWallop June 3rd 04 10:16 AM

ground floor chimney breast partial removal
 
JK wrote:
BigWallop wrote:
JK wrote:
I've read with some alarm old posts in the group about removing the
chimney breast from downstairs rooms. I don't really fancy the
expense of getting it completely removed and properly supported. But
is there a way of simply opening it up to somewhere near ceiling
height, leaving a pillar of bricks on either side and supporting
with an RSJ across those pillars. So it would be like a normal
fireplace, only a lot bigger, creating an alcove of usable space.
This is in a ground floor flat, no access to the upstairs at all
(though cooperative people upstairs who would allow anything that
was complying with regs and done by professionals).

Thanks,

John


There is no way to remove only a partial section of a chimney breast
because it is most commonly forming an actual part of the building
structural support. The only way is to remove all or none I'm afraid.


But all I'm proposing is something like a larger fireplace opening. As it
was built, it would have have an opening about 3' square with a lintel for
support. I'm just thinking I could make that higher and a bit wider, with a
bigger lintel.


You'd have to make sure that the surrounding narrower stonework will be able to
take the larger lintel and the same weight of house above it though. Some old
fireplaces and chimney breasts where built from rubble infill with a thin stone
facing, so the bits you see on the chimney breast may just be a built up
decorative facing to take the old fire surround.

There are also some old chimney breasts, the most common type, that are full
structural supports right down to the foundations and beyond, so need treated as
supporting structures. This type will need to be strutted with props and
battens and things before cutting anything out of them. The weights and sizes
need proper calculation to be sure that full weight above them will properly
supported. When you cut bits away you're actually making the remaining sections
narrower and weaker remember.

Weaken the stonework in anyway without being aware of the weight that you're
about to place on a larger opening is a really stupid idea, and it may mean
you'd have to place upright beams from the actual foundations of the house
before you place a lintel across them to take the full weight of the rest of the
house again.

Or you could just bash a bigger hole out and fit a bigger lintel, then pray that
your gut feeling was correct. :-))

Call in some one who can actually look at the job and give you more advice on
this. Better safe than sorry, eh ?