Tony Lennard April 1st 04 06:19 PM

relacing pendant light fitting
 
Hello all,

I'm replacing a pendant light fitting, unfortunately the switch cable is not
marked. Also, the two wires going to the light bulb are also not marked.

Is there a way to work out which of the black wires is the switch cable?

Thanks

Tony Lennard



Hugh April 1st 04 06:35 PM

relacing pendant light fitting
 
one of the black wires should have a red sleeve (bit of red insulating
tape) - if so, that's the switch line.
If not,
Is the old fitting still connected?
Are there 2 or 3 wires going in to the fitting?
Let us know first.
Hugh


--
----------------------------------------------------------------------------
---------
view my philatelic items for sale on ebay at:
http://tinyurl.com/l32i
"Tony Lennard" wrote in message
...
Hello all,

I'm replacing a pendant light fitting, unfortunately the switch cable is

not
marked. Also, the two wires going to the light bulb are also not marked.

Is there a way to work out which of the black wires is the switch cable?

Thanks

Tony Lennard





Lurch April 1st 04 09:05 PM

relacing pendant light fitting
 
On Thu, 1 Apr 2004 18:19:30 +0100, in uk.d-i-y "Tony Lennard"
strung together this:

Hello all,

I'm replacing a pendant light fitting, unfortunately the switch cable is not
marked. Also, the two wires going to the light bulb are also not marked.

Is there a way to work out which of the black wires is the switch cable?

If the inside of the pendant has;

1 black cable connected to the brown flex
3 reds connected in the middle in 'loop'
2 blacks connected to the blue flex

Then the single black is the switch and the two blacks are the
neutrals, most probably.

If it's anything different you will have to get a tester out and
check, with the light switched on, which black is live, and which
isn't in respect to earth.
--

SJW
A.C.S. Ltd.