CANNON
CAMBRIDGE MK2 Main Oven: Once the burner is ignited, it operates in 'SAFETY MODE' (low flame) after 1 minute the burner should operate with a 'FULL FLAME', but the flame stays in Safety Mode. Note: The grill, top oven & hotplates work & the cooker is not set for an AUTO COOKING PROGRAMME. Any ideas? |
#2
|
|||
|
|||
Gas cooker problem
In message , Rich
writes CANNON CAMBRIDGE MK2 Main Oven: Once the burner is ignited, it operates in 'SAFETY MODE' (low flame) after 1 minute the burner should operate with a 'FULL FLAME', but the flame stays in Safety Mode. The bi-metallic safety device has failed or is covered in gunge(TM). -- dave @ stejonda |
#3
|
|||
|
|||
Gas cooker problem
On Fri, 12 Mar 2004 15:34:46 +0000, Rich wrote:
CANNON CAMBRIDGE MK2 Main Oven: Once the burner is ignited, it operates in 'SAFETY MODE' (low flame) after 1 minute the burner should operate with a 'FULL FLAME', but the flame stays in Safety Mode. Note: The grill, top oven & hotplates work & the cooker is not set for an AUTO COOKING PROGRAMME. Any ideas? The over whelming majority of ovens use a metal bulb flame sensor which operates on the gas valve to move the flame up to the full rate. However the themrostat could have gone wrong: 1) Check you don't have a duff themrostat by turning to 'Regulo 9' 2) Chekc that there is nothing stopping the low-rate flame from heating the flame sensor bulb. If both of the above don't help then you are looking at the a new gas valve for the oven. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Electrics - Replace full electric cooker with a duel fuel cooker | UK diy | |||
Electrical - Rangemaster p90 all gas | UK diy | |||
Connecting Delinghi Gas Cooker to flexible (threaded) hose connector | UK diy | |||
Cooker Socket over Cooker? | UK diy |