On 15/06/2021 13:46, Tricky Dicky wrote:
On Monday, June 14, 2021 at 11:13:33 PM UTC+1, Grumps wrote:
I think I'm going mad! Am I correct in saying that a dry lining
back box does not need to be screwed to a stud or noggin? Screwing
only applies if fitting a steel box in this location.


I think most electricians prefer the metal box on a noggin especially
if on first fix they have access to the stud work only using dry
lining boxes when an additional socket is mounted in an existing
wall. The main reason I am told is that the front lip of the dry
line box is often visible especially when using some of the
decorative outlets.

I have seen an example of an electrician fixing a metal box to an
existing studded wall by glueing a suitable spacer piece to the other
PB back then screwing the box to the spacer.


Yup that works well IME - also gives you a fireproof and earthed back
box which can matter in some cases.


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/

  #12   Report Post  
Old June 15th 21, 05:00 PM posted to uk.d-i-y
external usenet poster
 
First recorded activity by DIYBanter: Jun 2014
Posts: 6,213
Default Back boxes for plasterboard walls

On 15/06/2021 13:27, JohnP wrote:
r.


I guess some people just fail to get the correct back box for the job and
become inventive.


Or, where they need to put a backbox, there is a noggin (partly) in
the way, so the clips are tricky to engage.
  #13   Report Post  
Old June 15th 21, 06:10 PM posted to uk.d-i-y
external usenet poster
 
First recorded activity by DIYBanter: Jul 2006
Posts: 43,075
Default Back boxes for plasterboard walls

In article ,
Tricky Dicky wrote:
I have seen an example of an electrician fixing a metal box to an
existing studded wall by glueing a suitable spacer piece to the other PB
back then screwing the box to the spacer.


Here, I generally use battens either side of the metal box fixed through
the plasterboard with brass screws. Then just fill the heads. Saves
messing around waiting for glue to dry. Of course if working in an already
decorated room, glue may be required. You often have to drill holes in
some makes of boxes too for the screws between that and the battens.

Of course for DIY, it's only my time. I doubt a pro wants the fiddle.

--
*I'm not a paranoid, deranged millionaire. Dammit, I'm a billionaire.

Dave Plowman London SW
To e-mail, change noise into sound.
  #14   Report Post  
Old June 15th 21, 07:10 PM posted to uk.d-i-y
ARW ARW is offline
external usenet poster
 
First recorded activity by DIYBanter: Aug 2012
Posts: 10,161
Default Back boxes for plasterboard walls

On 15/06/2021 13:46, Tricky Dicky wrote:
On Monday, June 14, 2021 at 11:13:33 PM UTC+1, Grumps wrote:
I think I'm going mad!
Am I correct in saying that a dry lining back box does not need to be
screwed to a stud or noggin? Screwing only applies if fitting a steel
box in this location.


I think most electricians prefer the metal box on a noggin especially if on first fix they have access to the stud work only using dry lining boxes when an additional socket is mounted in an existing wall. The main reason I am told is that the front lip of the dry line box is often visible especially when using some of the decorative outlets.


It should not be visible if the dry liner is fitted before the wall is
skimmed.

But yes I am a noggin and metal backbox man.


--
Adam
  #15   Report Post  
Old June 15th 21, 07:43 PM posted to uk.d-i-y
external usenet poster
 
First recorded activity by DIYBanter: Dec 2020
Posts: 1,591
Default Back boxes for plasterboard walls

On 15/06/2021 18:10, ARW wrote:
On 15/06/2021 13:46, Tricky Dicky wrote:
On Monday, June 14, 2021 at 11:13:33 PM UTC+1, Grumps wrote:
I think I'm going mad!
Am I correct in saying that a dry lining back box does not need to be
screwed to a stud or noggin? Screwing only applies if fitting a steel
box in this location.


I think most electricians prefer the metal box on a noggin especially
if on first fix they have access to the stud work only using dry
lining boxes when an additional socket is mounted in an existing wall.
The main reason I am told is thatÂ* the front lip of the dry line box
is often visible especially when using some of the decorative outlets.


It should not be visible if the dry liner is fitted before the wall is
skimmed.

But yes I am a noggin and metal backbox man.


Isn't that because you wire and fit back boxes before the plasterboard
is possibly even on site?


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
sinking back boxes into walls - gone too deep imanc UK diy 37 May 15th 13 11:57 PM
Cheap Storage Boxes | Cheap Moving Boxes | Smart Storage Boxes rozy zenstin Metalworking 0 October 25th 10 03:24 PM
Fast and accurate way to cut plasterboard to match patress boxes -how do *you* do it? [email protected] UK diy 14 January 29th 10 06:27 PM
New Construction: Aligning Electric Gang Boxes With PlasterBoard Front Surface ? Robert11 Home Repair 2 June 17th 05 04:55 PM
Building code: Electrical boxes back-to-back, how many [email protected]_dot_los-gatos_dot_ca.us Home Ownership 1 March 15th 04 08:34 PM


All times are GMT +1. The time now is 01:32 PM.

Powered by vBulletin® Copyright ©2000 - 2022, Jelsoft Enterprises Ltd.
Copyright ©2004-2022 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"

 

Copyright © 2017