I'm replacing wiring to a socket that was run on a spur underneath the carpet
(!). I have some skirting trunking that will take care of running it around
the edge of the room, and I'm planning to extend the ring using 2.5mm2 T&E
in the bottom of the trunking.

What are the requirements for cable attachment in this scenario? Ordinarily
I'd assume it would need clipping, but is that the case inside trunking?
It's literally resting on the floor at this point, so there's no need to
support it at all, and it's protected at the front by the face of the
trunking. I will obviously clip it where it emerges from the trunking to
sockets.

I ask because it's a bit tight and so it's going to be awkward to clip
inside the slot it runs in - the slot which also means it's constrained top
and bottom. It isn't anywhere near a route of egress and if the trunking
melted it would fall about a millimetre.

Does being in floor trunking count as sufficient attachment?

Thanks
Theo
  #2   Report Post  
Posted to uk.d-i-y
ARW ARW is offline
external usenet poster
 
Posts: 10,161
Default Cable clipping trunked T&E

On 23/08/2020 16:08, Theo wrote:
I'm replacing wiring to a socket that was run on a spur underneath the carpet
(!). I have some skirting trunking that will take care of running it around
the edge of the room, and I'm planning to extend the ring using 2.5mm2 T&E
in the bottom of the trunking.

What are the requirements for cable attachment in this scenario? Ordinarily
I'd assume it would need clipping, but is that the case inside trunking?
It's literally resting on the floor at this point, so there's no need to
support it at all, and it's protected at the front by the face of the
trunking. I will obviously clip it where it emerges from the trunking to
sockets.

I ask because it's a bit tight and so it's going to be awkward to clip
inside the slot it runs in - the slot which also means it's constrained top
and bottom. It isn't anywhere near a route of egress and if the trunking
melted it would fall about a millimetre.

Does being in floor trunking count as sufficient attachment?



I would not use any "fire rated" clips in your scenario.

--
Adam
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 12,364
Default Cable clipping trunked T&E

On Sunday, 23 August 2020 16:08:13 UTC+1, Theo wrote:

I'm replacing wiring to a socket that was run on a spur underneath the carpet
(!). I have some skirting trunking that will take care of running it around
the edge of the room, and I'm planning to extend the ring using 2.5mm2 T&E
in the bottom of the trunking.

What are the requirements for cable attachment in this scenario? Ordinarily
I'd assume it would need clipping, but is that the case inside trunking?


no

It's literally resting on the floor at this point, so there's no need to
support it at all, and it's protected at the front by the face of the
trunking. I will obviously clip it where it emerges from the trunking to
sockets.


it's more common to run the trunking to the socket

I ask because it's a bit tight and so it's going to be awkward to clip
inside the slot it runs in - the slot which also means it's constrained top
and bottom. It isn't anywhere near a route of egress and if the trunking
melted it would fall about a millimetre.

Does being in floor trunking count as sufficient attachment?

Thanks
Theo


if it won't fall onto people in a fire it doesn't need metal clips


NT
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Marshall JTM/1962 , of 1998, amp clipping N_Cook Electronics Repair 16 November 7th 12 05:42 PM
Is my receiver clipping? Shutting down when volume is high. Cartrivision1 Electronics Repair 8 March 14th 06 06:15 PM
clipping cables to stone walls Fash UK diy 13 July 17th 05 10:10 AM
need clamping & clipping circuit help to keep steady 30v [email protected] Electronics Repair 1 May 10th 05 08:52 PM
Pulling cable through with existing one / Clipping cable in loft Mike Hall UK diy 17 January 12th 04 12:52 PM


All times are GMT +1. The time now is 06:26 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"