This has been somewhat covered in a couple of recent threads but they are
long so I'm trying to pick up on a few points. (1) The maximum power output of a UK electric shower is around 10 kW. The output of a small(ish) combi boiler is around 28 kW. So the combi should be able to apply 2.8 times the heat to incoming cold water and so (I assume) heat 2.8 times the amount of incoming water to an acceptable temperature compared to the electric shower. (2) Electricity costs around 3 times gas (per unit of energy) which kind of balances out. You can either have about 3 times the hot water in your shower for the same price or save money each time you shower at lower flow rates. I think most people would go for the more satisfying shower which does reduce/eliminate the cost saving from using a combi boiler. {Wanders off into speculation} Hmmm....what is the maximum (ignoring wiring restrictions for the moment) that you could get out of a UK domestic 2 phase supply? Simplistically, using (Volts * Amps = Watts) and rounding outrageously 4 amps = 1 kW. So again rounding outrageously a 13 Amp circuit could support a 3 kW fire, for example. If your mains incomer is 60 amps (a lot go up to 100 amps) then you might be able to draw (60/4) = 15 kW is nothing else is powered up, or (100/4) = 25 kW for a 100 amp supply. I realise there are all sorts of minor (hah!) constraints but if you had a 100 amp incomer then is there any reason that you couldn't (with some very thick cabling) take 60 amps for a shower giving you 15 kW of toasty goodness? I do note that taking all the output from a 100 amp incomer still gives you less heat input than a combi boiler. 3 phase electric shower, anyone? Cheers Dave R -- AMD FX-6300 in GA-990X-Gaming SLI-CF running Windows 7 Pro x64 --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com/antivirus |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Boilers DHW baths and showers (dare I ask?) | UK diy | |||
Bathtub, surround quandry...acrylic, fiberglass, Swanstone, Veritek, etc.etc.etc. | Home Repair | |||
Boilers, boilers.. | UK diy | |||
Showers compatible with combi boilers | Home Repair | |||
Showers compatible with combi boilers | Home Repair |