Richardmerri[_2_] March 27th 18 05:43 PM

SCANTRONIC 9448+ intruder alarm
 
Hello all... My 9448+ has gone 'rogue' for when we try to set it to go out the normal beep, beep sounds for about 30 seconds and then the internal sounder goes off and just keeps going but the external sounder does not sound at all. The zone 6 PA (Panic Alarm) led also lights and stays lit and all we can do is enter our access code to shut the thing down. I have the full engineers manual but I can't find anything that might help within it! The USER GUIDE tells me to 're-set the panic button' but nowhere can I discover how to do that! Maybe this is 'finger trouble'? Any help would be gratefully appreciated.

Richard.

Bill Wright[_3_] March 27th 18 09:46 PM

SCANTRONIC 9448+ intruder alarm
 
On 27/03/2018 17:43, Richardmerri wrote:
Hello all... My 9448+ has gone 'rogue' for when we try to set it to go out the normal beep, beep sounds for about 30 seconds and then the internal sounder goes off and just keeps going but the external sounder does not sound at all. The zone 6 PA (Panic Alarm) led also lights and stays lit and all we can do is enter our access code to shut the thing down. I have the full engineers manual but I can't find anything that might help within it! The USER GUIDE tells me to 're-set the panic button' but nowhere can I discover how to do that! Maybe this is 'finger trouble'? Any help would be gratefully appreciated.

Richard.

Disconnect Zone 6 at the panel or replace the connection with a shorting
U loop. See what happens.

Bill

Tim+[_5_] March 27th 18 09:56 PM

SCANTRONIC 9448+ intruder alarm
 
Richardmerri wrote:
Hello all... My 9448+ has gone 'rogue' for when we try to set it to go
out the normal beep, beep sounds for about 30 seconds and then the
internal sounder goes off and just keeps going but the external sounder
does not sound at all. The zone 6 PA (Panic Alarm) led also lights and
stays lit and all we can do is enter our access code to shut the thing
down. I have the full engineers manual but I can't find anything that
might help within it! The USER GUIDE tells me to 're-set the panic
button' but nowhere can I discover how to do that! Maybe this is 'finger
trouble'? Any help would be gratefully appreciated.

Richard.


When our house had a €śpanic button€ť it had a key to reset the button,
presumably to stop an intruder easily resetting it.

Tim

--
Please don't feed the trolls

[email protected] March 28th 18 09:11 AM

SCANTRONIC 9448+ intruder alarm
 
On 27/03/2018 21:56, Tim+ wrote:
Richardmerri wrote:

.... snipped

Richard.


When our house had a €śpanic button€ť it had a key to reset the button,
presumably to stop an intruder easily resetting it.

Tim

That's interesting.
We "inherited" some panic buttons when we bought this house. I haven't
tested them but had wondered why they had key holes but haven't got
around to finding out - or finding a key!

AlanC March 28th 18 09:21 AM

SCANTRONIC 9448+ intruder alarm
 
On Wednesday, 28 March 2018 09:11:44 UTC+1, wrote:

That's interesting.
We "inherited" some panic buttons when we bought this house. I haven't
tested them but had wondered why they had key holes but haven't got
around to finding out - or finding a key!


Our panic button consists of a big red button that, when pressed, cannot be returned to its off position without the key. The key is pretty basic. It just rotates in its hole and pushes the button back up.

If we try and disarm the alarm while the button is still down, it just re-triggers, so a good idea to have the key handy if you accidentally press it (or someone presses it out of curiosity!)

Agree with the previous comment about disabling the zone. You can also set the zone to unused while you fix/replace the panic button.

AlanC March 28th 18 09:25 AM

SCANTRONIC 9448+ intruder alarm
 
On Wednesday, 28 March 2018 09:21:53 UTC+1, AlanC wrote:
On Wednesday, 28 March 2018 09:11:44 UTC+1, wrote:

That's interesting.
We "inherited" some panic buttons when we bought this house. I haven't
tested them but had wondered why they had key holes but haven't got
around to finding out - or finding a key!


Our panic button consists of a big red button that, when pressed, cannot be returned to its off position without the key. The key is pretty basic. It just rotates in its hole and pushes the button back up.

If we try and disarm the alarm while the button is still down, it just re-triggers, so a good idea to have the key handy if you accidentally press it (or someone presses it out of curiosity!)

Agree with the previous comment about disabling the zone. You can also set the zone to unused while you fix/replace the panic button.


Forgot to say, the user manual probably wont be much help to you. You will likely need the installation manual and the engineer code.

Richardmerri[_2_] March 29th 18 11:31 AM

SCANTRONIC 9448+ intruder alarm
 
On Tuesday, 27 March 2018 21:46:06 UTC+1, Bill Wright wrote:
On 27/03/2018 17:43, Richardmerri wrote:
Hello all... My 9448+ has gone 'rogue' for when we try to set it to go out the normal beep, beep sounds for about 30 seconds and then the internal sounder goes off and just keeps going but the external sounder does not sound at all. The zone 6 PA (Panic Alarm) led also lights and stays lit and all we can do is enter our access code to shut the thing down. I have the full engineers manual but I can't find anything that might help within it! The USER GUIDE tells me to 're-set the panic button' but nowhere can I discover how to do that! Maybe this is 'finger trouble'? Any help would be gratefully appreciated.

Richard.

Disconnect Zone 6 at the panel or replace the connection with a shorting
U loop. See what happens.

Bill


Dear Bill... Thank you indeed for your direction here! The problem is now solved but I have no idea as to what was the original cause! Zone 6 was not connected at all, the connections were open circuit and 'floating', I don't know if the board is essentially CMOS or TTL but there are quite a number of discrete devices on the pcb. If it is CMOS the o/c could possibly have floated to a logical high (1) do you think? I have done what you suggest and put a shorting link across the Zone 6 terminals and then I, once again, re-set the system to it's initial default settings i.e. code 1234 etc. by putting a s/c across the reset Molex pins with the mains and battery disconnected, re-connecting the battery and then the mains supply... et voila!! The rogue behavior had ceased :-) ...and now all appears to be well. So Bill, thanks again...

Richard.

Richardmerri[_2_] March 29th 18 11:37 AM

SCANTRONIC 9448+ intruder alarm
 
On Wednesday, 28 March 2018 09:25:13 UTC+1, AlanC wrote:
On Wednesday, 28 March 2018 09:21:53 UTC+1, AlanC wrote:
On Wednesday, 28 March 2018 09:11:44 UTC+1, wrote:

That's interesting.
We "inherited" some panic buttons when we bought this house. I haven't
tested them but had wondered why they had key holes but haven't got
around to finding out - or finding a key!


Our panic button consists of a big red button that, when pressed, cannot be returned to its off position without the key. The key is pretty basic. It just rotates in its hole and pushes the button back up.

If we try and disarm the alarm while the button is still down, it just re-triggers, so a good idea to have the key handy if you accidentally press it (or someone presses it out of curiosity!)

Agree with the previous comment about disabling the zone. You can also set the zone to unused while you fix/replace the panic button.


Forgot to say, the user manual probably wont be much help to you. You will likely need the installation manual and the engineer code.


Hi Alan... Thanks for your help and thanks to all who responded to my cry for help! The problem is now fixed see detailed explanation above...

Thanks again Alan and all...

Richard.