Peter G
 
Posts: n/a
Default Boiler Replacement

Dear All Happy Xmas for the coming season (04 that is)

I have a Glow Worm Fuel Saver MkII balanced flue boiler that has been in my
4
bed detached house since it was built 15 years ago. I have often had
problems with the pilot light going out and it is not the easiest to relight
especially for my wife. Apart from the pilot light the boiler has been very
reliable. Would someone be kind enough to advice me on whether I should
consider a replacement?

How much more efficient are the modern boilers and if replaced any guess on
the % yearly saving over this boiler.
What make and model should I be looking at how much should I expect to pay
for the boiler and the skill of a tradesman to change.

Many thanks

Pete



  #2   Report Post  
Andy R
 
Posts: n/a
Default Boiler Replacement


"Peter G" wrote in message
...
Dear All Happy Xmas for the coming season (04 that is)

I have a Glow Worm Fuel Saver MkII balanced flue boiler that has been in

my
4
bed detached house since it was built 15 years ago. I have often had
problems with the pilot light going out and it is not the easiest to

relight
especially for my wife. Apart from the pilot light the boiler has been

very
reliable. Would someone be kind enough to advice me on whether I should
consider a replacement?

How much more efficient are the modern boilers and if replaced any guess

on
the % yearly saving over this boiler.
What make and model should I be looking at how much should I expect to pay
for the boiler and the skill of a tradesman to change.


IMHO if it keeps going then leave it. The old boilers need virtually no
attention and last for 'ever'. I had a 30 year old boiler that worked fine
if a little inefficiently. When we had the kitchen redesigned I replaced it
with a combi, much more efficient, it saved me about £6 per month on gas.
However, at £800 for the new boiler with installation, assuming it never
goes wrong, it's going to take an awfully long time to recover the money and
because there are so many more parts in it it's bound to go wrong more than
the old one did making the payback time even longer.

Rgds

Andy R


  #3   Report Post  
Andy Hall
 
Posts: n/a
Default Boiler Replacement

On Fri, 9 Jan 2004 13:49:03 -0000, "Peter G"
wrote:

Dear All Happy Xmas for the coming season (04 that is)

I have a Glow Worm Fuel Saver MkII balanced flue boiler that has been in my
4
bed detached house since it was built 15 years ago. I have often had
problems with the pilot light going out and it is not the easiest to relight
especially for my wife. Apart from the pilot light the boiler has been very
reliable. Would someone be kind enough to advice me on whether I should
consider a replacement?

How much more efficient are the modern boilers and if replaced any guess on
the % yearly saving over this boiler.
What make and model should I be looking at how much should I expect to pay
for the boiler and the skill of a tradesman to change.

Many thanks

Pete


I've been there and have the T-shirt, Peter, with the self-same
boiler. Mine was installed when the house was built in 1985 and
replaced last year.

The pilot light going out issue happened on mine and is generally
either because the thermocouple is failing or because the pilot light
jet is dirty or perhaps set too low. The thermocouple is a metal
capsule in the pilot flame, together with a capillary tube which then
goes out of the combustion compartment and to a connector at the gas
valve. Replacing it is very easy and cheap (they are generic parts
at about £3 from a plumber's merchant.).

If it isn't that, then it would likely be the pilot jet adjustment or
cleaning, or there is a possibility of the gas valve having a problem.
One of these would cost typically in the £50-70 area for the part.

On mine, the thermocouple failed, and then the thermostat, and it was
at that point that I started to consider a replacement rather than
throwing good money away on something at the end of its useful life.
To be honest, the manuafacturing quality of these boilers was not
great to begin with - every time I took the covers off for a repair, I
would cut myself on the sharp metal pieces inside.

Boiler efficiencies have improved enormously since this model.
There is a UK testing method and database of boilers at www.sedbuk.com
The principle behind this is a testing method which looks at the UK
climate and factors the seasonal variations into boiler efficiency
calculations and measurements, rather than just taking the raw
efficiency figures of energy in and energy out. There is also a
Europe wide measuring system under discussion, but the SEDBUK
information is a useful guide for the moment. They do point out that
you should not use the last fraction of a percent to select a boiler.

From this, if you look up the Glow Worm Fuelsaver, you will find that
it has a SEDBUK efficiency of 65%. New boilers being installed
today, are required under the Building Regulations to have a SEDBUK
efficiency of at least 78%. From a technology perspective, updated
versions of conventional boilers just about manage to scrape into this
limit, and you would see Mk3 and 'e' versions to do this.
Manufacturers used various means to be able to continue selling them.

If you want to, there is nothing to stop you buying a replacement
boiler at this efficiency level if you choose. However, you can do a
great deal better using a condensing boiler. These work by having
a larger and more efficient heat exchanger and by arranging to
condense steam from the combustion process to water or water vapour.
The principle here is of the latent heat of condensation, whereby heat
energy is released when a gas condenses to its liquid phase. It's the
opposite of evaporation - think about sweating making you cool.

The effect is that you can achieve an efficiency, as measured by the
SEDBUK methods of 90-91%. Compared with 65%, this is a huge saving.
I have had a condensing model for just over a year and am seeing
25-30% savings on gas consumption - pretty much the predicted figures.
It's worth noting that current government thinking is to raise the bar
on efficiency ratings to 86% next year. Effectively this will take
all of the older technology products off the market anyway.

For the most part, current and new generation condensing boilers are
of good quality. Early generation UK manufactured ones gained a poor
reputation simply because they were poorly designed and used the wrong
materials. One of the aspects of condensing boilers is that the
condensate produced is slightly acidic and that has to be accounted
for in the materials used. Generally in modern products it is. The
condensate is fed from the boiler via a plastic pipe to a convenient
drain. Condensing boilers have been in use in Holland and Germany
for at least 15 years, and so the early issues were resolved a long
time ago.

In terms of cost, you will pay approximately £200 more for an
equivalent model condensing boiler, or as little as £100 between a not
quite bottom of the range conventional boiler and a reasonable
condensing model.

People here have seen good results with products from Keston and
Vaillant and these come in at the £700-900 range.

It's difficult to put a figure on the labour involved because it will
tend to vary by what is involved. Some boilers will operate on an
open vented environment such as you have today, others require the
system to be sealed, yet others do either. Changing the system over
is not a major issue in most cases.

Another useful upgrade while you are doing this would be to improve
the hot water system by replacing the cylinder with a fast recovery
type.



..andy

To email, substitute .nospam with .gl
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Reasonable price for a replacement CH boiler? Hugo Nebula UK diy 18 November 20th 03 08:01 PM
Replacement for old high output combi boiler David C. Partridge UK diy 3 November 15th 03 09:21 PM
Calculating heat output for a replacement boiler bodger UK diy 7 November 11th 03 12:18 AM
Replacement boiler advice please. Peter Smithson UK diy 18 October 5th 03 09:40 AM


All times are GMT +1. The time now is 01:44 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"