Michael January 1st 04 01:47 PM

Triton T200RE
 
I have recently moved to a new house and the existing electric shower
has a pipe that appears to have some sort of overflow pipe coming from
the power box. This now has water coming through it and connects to
nothing so has caused a leak in the ceiling. However I have directed
it to an over flow pipe so that for the mean time it pours outside if
the shower is in use. I could direct it into the main hot water tank,
but is this OK to do so? Is it mean't to have water coming out
everytime the shower is in use? Is there a proper way to deal with the
water other than the above.

The shower is a Triton T200RE that has a flush fitting control panel
and a separate power box fitted within the roof space.

Stuart January 1st 04 03:58 PM

Triton T200RE
 
On 1 Jan 2004 05:47:03 -0800, (Michael) wrote:

I have recently moved to a new house and the existing electric shower
has a pipe that appears to have some sort of overflow pipe coming from
the power box. This now has water coming through it and connects to
nothing so has caused a leak in the ceiling. However I have directed
it to an over flow pipe so that for the mean time it pours outside if
the shower is in use. I could direct it into the main hot water tank,
but is this OK to do so? Is it mean't to have water coming out
everytime the shower is in use? Is there a proper way to deal with the
water other than the above.

The shower is a Triton T200RE that has a flush fitting control panel
and a separate power box fitted within the roof space.


Check out
www.tritonshowers.co.uk
There is a Shower Doctor section .

Could it be the Pressure Relief Device has been activated ???


"If water is leaking from a clear plastic tube at the bottom of the unit,
then the Pressure Relief Device (PRD) has been activated. A replacement
can be ordered from the Triton Spares department (024 76372222). "

Stuart


--

"YESTERDAY is history,TOMORROW is a mystery,TODAY is a gift

That is why it is called the present "

MrCheerful January 1st 04 07:42 PM

Triton T200RE
 

"Michael" wrote in message
om...
I have recently moved to a new house and the existing electric shower
has a pipe that appears to have some sort of overflow pipe coming from
the power box. This now has water coming through it and connects to
nothing so has caused a leak in the ceiling. However I have directed
it to an over flow pipe so that for the mean time it pours outside if
the shower is in use. I could direct it into the main hot water tank,
but is this OK to do so? Is it mean't to have water coming out
everytime the shower is in use? Is there a proper way to deal with the
water other than the above.

The shower is a Triton T200RE that has a flush fitting control panel
and a separate power box fitted within the roof space.


I have one of these and when the PRD failed water came out as you describe.
It is like a metal flying saucer with a diaphragm in it.

I rang triton and a new one came very quickly and was quite easy to fit.

MrCheerful



Ed Sirett January 1st 04 08:38 PM

Triton T200RE
 
On Thu, 01 Jan 2004 15:58:38 +0000, Stuart wrote:

On 1 Jan 2004 05:47:03 -0800, (Michael) wrote:

I have recently moved to a new house and the existing electric shower
has a pipe that appears to have some sort of overflow pipe coming from
the power box. This now has water coming through it and connects to
nothing so has caused a leak in the ceiling. However I have directed
it to an over flow pipe so that for the mean time it pours outside if
the shower is in use. I could direct it into the main hot water tank,
but is this OK to do so? Is it mean't to have water coming out
everytime the shower is in use? Is there a proper way to deal with the
water other than the above.

The shower is a Triton T200RE that has a flush fitting control panel
and a separate power box fitted within the roof space.


Check out
www.tritonshowers.co.uk
There is a Shower Doctor section .

Could it be the Pressure Relief Device has been activated ???


"If water is leaking from a clear plastic tube at the bottom of the unit,
then the Pressure Relief Device (PRD) has been activated. A replacement
can be ordered from the Triton Spares department (024 76372222). "


I would go as far as to say
1) it is the PRd.
2) The shower has expired.
3) Order a replacement of the same electric power and adjust wiring and
plumbing as needed.





--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html



MrCheerful January 1st 04 10:19 PM

Triton T200RE
 

"Ed Sirett" wrote in message
n.co.uk...
On Thu, 01 Jan 2004 15:58:38 +0000, Stuart wrote:

On 1 Jan 2004 05:47:03 -0800, (Michael) wrote:

I have recently moved to a new house and the existing electric shower
has a pipe that appears to have some sort of overflow pipe coming from
the power box. This now has water coming through it and connects to
nothing so has caused a leak in the ceiling. However I have directed
it to an over flow pipe so that for the mean time it pours outside if
the shower is in use. I could direct it into the main hot water tank,
but is this OK to do so? Is it mean't to have water coming out
everytime the shower is in use? Is there a proper way to deal with the
water other than the above.

The shower is a Triton T200RE that has a flush fitting control panel
and a separate power box fitted within the roof space.


Check out
www.tritonshowers.co.uk
There is a Shower Doctor section .

Could it be the Pressure Relief Device has been activated ???


"If water is leaking from a clear plastic tube at the bottom of the

unit,
then the Pressure Relief Device (PRD) has been activated. A replacement
can be ordered from the Triton Spares department (024 76372222). "


I would go as far as to say
1) it is the PRd.
2) The shower has expired.
3) Order a replacement of the same electric power and adjust wiring and
plumbing as needed.





--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html



This shower unit is like no other I have seen. The control unit is
electronic low voltage fitted flush to the wall, the heater unit is remote.

When I bought mine it was 200 pounds while a standard one was about 50 quid
upwards. Mine has been in very regular use (at least an hour a day) for
twenty years, the only breakdown was the prd after about ten years, the
shower hose also failed . I have remade some of the electrical connections
on the heater unit. It has never even had the shower head descaled as I
run a water softener. Overall I would say it is a very good shower unit,
but the design is such that a replacement equivalent would be difficult, I
expect.

MrCheerful



PetshopPete August 12th 19 01:14 PM

Triton T200RE
 
replying to Ed Sirett, PetshopPete wrote:
Its just the clear overflow tube that is fed outside

--
for full context, visit https://www.homeownershub.com/uk-diy...0re-42721-.htm



[email protected] August 13th 19 09:55 AM

Triton T200RE
 
On Monday, 12 August 2019 13:14:03 UTC+1, PetshopPete wrote:
replying to Ed Sirett, PetshopPete wrote:
Its just the clear overflow tube that is fed outside


He's been waiting 15 years to find that out.


All times are GMT +1. The time now is 05:24 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 DIYbanter