Push fit plumbing
I am about to replace a mixer tap the old one has been plumbed in with 15mm push fit fittings see below;
http://www.screwfix.com/p/yorkshire-...ails_container The new one has flexible tails, so just a case of cutting the pipes at some convenient point and tightening the compression fittings on. However, this is my first experience of these push fit fittings and I was wondering how careful I need to be, will causing them to twist result in leaks or are they fairly robust? Richard |
Push fit plumbing
On 09-Sep-16 11:08 AM, Tricky Dicky wrote:
I am about to replace a mixer tap the old one has been plumbed in with 15mm push fit fittings see below; http://www.screwfix.com/p/yorkshire-...ails_container The new one has flexible tails, so just a case of cutting the pipes at some convenient point and tightening the compression fittings on. However, this is my first experience of these push fit fittings and I was wondering how careful I need to be, will causing them to twist result in leaks or are they fairly robust? I've not used those, but I have used push-fit connectors on air lines. If those fittings are anything like airline fittings, twisting them once they are in place is not practical. IME, the most important thing is to ensure that the end of the pipe is cut square, properly de-burred and clean on the outside. -- -- Colin Bignell |
Push fit plumbing
In article ,
Nightjar writes: On 09-Sep-16 11:08 AM, Tricky Dicky wrote: I am about to replace a mixer tap the old one has been plumbed in with 15mm push fit fittings see below; http://www.screwfix.com/p/yorkshire-...ails_container The new one has flexible tails, so just a case of cutting the pipes at some convenient point and tightening the compression fittings on. However, this is my first experience of these push fit fittings and I was wondering how careful I need to be, will causing them to twist result in leaks or are they fairly robust? I've not used those, but I have used push-fit connectors on air lines. If those fittings are anything like airline fittings, twisting them once they are in place is not practical. IME, the most important thing is to ensure that the end of the pipe is cut square, properly de-burred and clean on the outside. I haven't used those metal ones, but the plastic JG pushfit connectors twist quite easily, because the grab ring turns in the fitting. If you actually intend to do this, I would use a little silicone grease on the O-ring so it slides easily on the pipe as it is turned, reducing any chance of snagging it. BTW, if you are going to use pushfit, cut the pipe with a pipe cutter rather than a hacksaw, as the fitting will then easily slide on without damaging the o-ring seal. -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |
Push fit plumbing
As suspected it was difficult to prevent those sections of the push fit plumbing that would remain from moving and twisting whilst making up the new connections. Fortunetly although fittings moved and pipes twisted so far no leaks, wether I have been lucky and got away with it or if this is normal I do not know.
It feels a different kind of plumbing where the integrity of soldered and compression jointed pipe work remains rigid and to some extent self supporting to one with a greater reliance on pipe clips. Richard |
Push fit plumbing
In article ,
Tricky Dicky writes: As suspected it was difficult to prevent those sections of the push fit plu= mbing that would remain from moving and twisting whilst making up the new c= onnections. Fortunetly although fittings moved and pipes twisted so far no = leaks, wether I have been lucky and got away with it or if this is normal I= do not know. It feels a different kind of plumbing where the integrity of soldered and c= ompression jointed pipe work remains rigid and to some extent self supporti= ng to one with a greater reliance on pipe clips. Pushfit pipes must enter the fittings in perfect alignment and without straining, and that may mean using pipe clips where you wouldn't need to for compression or soldered fittings. The O-rings have an expected life of 25 years in the high quality products (although I've had two which failed after 12 years, even though I use hardly any pushfit myself). -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |