Billy N October 31st 03 07:28 PM

Central Heating not Switching off
 
Hi I was wondering if anyone can help me with a problem that i have
with my ch. my heating and water are on continuoius and will not
switch of. I have tried switch it of at the
a) control panel but it still remains on
b) the room therostat, sill on
the only way i can get it to go off is if i switch the boiler
isolation switch off

Hope someone out there can help me.

Roger Mills October 31st 03 08:19 PM

Central Heating not Switching off
 

"Billy N" wrote in message
om...
Hi I was wondering if anyone can help me with a problem that i have
with my ch. my heating and water are on continuoius and will not
switch of. I have tried switch it of at the
a) control panel but it still remains on
b) the room therostat, sill on
the only way i can get it to go off is if i switch the boiler
isolation switch off

Hope someone out there can help me.


Sounds like you may have a frost stat which runs the CH when the outside
temperature falls to a certain level - even if it is otherwise switched off.
Try to find it, and check that it's not set at too high a temperature.

Roger



BigWallop October 31st 03 08:35 PM

Central Heating not Switching off
 

"Billy N" wrote in message
om...
Hi I was wondering if anyone can help me with a problem that i have
with my ch. my heating and water are on continuoius and will not
switch of. I have tried switch it of at the
a) control panel but it still remains on
b) the room therostat, sill on
the only way i can get it to go off is if i switch the boiler
isolation switch off

Hope someone out there can help me.


Make and model of the timer/programmer please ?

Same information on the boiler would help lots.

Age and layout of the system is even more of a help.



PoP October 31st 03 09:21 PM

Central Heating not Switching off
 
On 31 Oct 2003 11:28:45 -0800, (Billy N) wrote:

Hi I was wondering if anyone can help me with a problem that i have
with my ch. my heating and water are on continuoius and will not
switch of. I have tried switch it of at the
a) control panel but it still remains on
b) the room therostat, sill on
the only way i can get it to go off is if i switch the boiler
isolation switch off


Have you got a frost thermostat on the system? If so, check whether
that is overriding the control panel. It might just need resetting to
a lower temperature.

PoP


Billy N November 1st 03 11:01 AM

Central Heating not Switching off
 
"BigWallop" wrote in message ...
"Billy N" wrote in message
om...
Hi I was wondering if anyone can help me with a problem that i have
with my ch. my heating and water are on continuoius and will not
switch of. I have tried switch it of at the
a) control panel but it still remains on
b) the room therostat, sill on
the only way i can get it to go off is if i switch the boiler
isolation switch off

Hope someone out there can help me.


Make and model of the timer/programmer please ?

Same information on the boiler would help lots.

Age and layout of the system is even more of a help.


Thanks folks

Make & Model of Boiler: potterton Flamingo RS40s/50s
make & Model timer : landis & Gyr RWB2
AGE about : 20 years

Ed Sirett November 1st 03 12:39 PM

Central Heating not Switching off
 
On Fri, 31 Oct 2003 11:28:45 +0000, Billy N wrote:

Hi I was wondering if anyone can help me with a problem that i have
with my ch. my heating and water are on continuoius and will not
switch of. I have tried switch it of at the
a) control panel but it still remains on
b) the room therostat, sill on
the only way i can get it to go off is if i switch the boiler
isolation switch off

Hope someone out there can help me.


The main FAQ has a fair bit on controls heating controls.


--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html



BigWallop November 1st 03 04:42 PM

Central Heating not Switching off
 

"Billy N" wrote in message
om...
"BigWallop" wrote in message

...
"Billy N" wrote in message
om...
Hi I was wondering if anyone can help me with a problem that i have
with my ch. my heating and water are on continuoius and will not
switch of. I have tried switch it of at the
a) control panel but it still remains on
b) the room therostat, sill on
the only way i can get it to go off is if i switch the boiler
isolation switch off

Hope someone out there can help me.


Make and model of the timer/programmer please ?

Same information on the boiler would help lots.

Age and layout of the system is even more of a help.


Thanks folks

Make & Model of Boiler: potterton Flamingo RS40s/50s
make & Model timer : landis & Gyr RWB2
AGE about : 20 years


After ruling out the frost 'stat outside, it could be that the switch
terminals on the timer have eventually welded themselves together. If the
timer is the same age as the rest of the system, I'd start looking there.

You will need a meter that can produce its own readings in the Ohms range to
check it properly. Remove the timer from its back plate and check across
the HW and CH connections to see if they are opening and closing as they
should.