I've got a customer who owns a house divided into 6 x 1 bed flats. The top
floor flat rad is completely cold. Water comes out of the bleed as usual. The occupants of the other 5 rooms are all complaining that their rads get far too hot. All the rads seem to have a lockshield on both ends, so can't be adjusted. Why would that be? I could only check the rad in the flat below the top one, which was red hot, both valve fully open. Combi boiler pressure was down a little & output set at 56 degrees (LED display). I reckon the problem is the lack of adjustment on each rad, poor bugger on the top floor is loosing his share of heat to the over hot other 5. Can you buy replacement wheelhead caps in any of the sheds? Or is it another problem? -- Dave - The Medway Handyman www.medwayhandyman.co.uk 01634 717930 07850 597257 |
#2
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() "The Medway Handyman" wrote in message ... I've got a customer who owns a house divided into 6 x 1 bed flats. The top floor flat rad is completely cold. Water comes out of the bleed as usual. The occupants of the other 5 rooms are all complaining that their rads get far too hot. All the rads seem to have a lockshield on both ends, so can't be adjusted. Why would that be? I could only check the rad in the flat below the top one, which was red hot, both valve fully open. Combi boiler pressure was down a little & output set at 56 degrees (LED display). I reckon the problem is the lack of adjustment on each rad, poor bugger on the top floor is loosing his share of heat to the over hot other 5. So adjust them with an adjustable wrench to prove this. Turn some rads on the lower floors down to see if you can kick start the top floor. Adam |
#3
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Mon, 03 Mar 2008 19:32:18 +0000, The Medway Handyman wrote:
I've got a customer who owns a house divided into 6 x 1 bed flats. The top floor flat rad is completely cold. Water comes out of the bleed as usual. The occupants of the other 5 rooms are all complaining that their rads get far too hot. All the rads seem to have a lockshield on both ends, so can't be adjusted. Why would that be? I could only check the rad in the flat below the top one, which was red hot, both valve fully open. Combi boiler pressure was down a little & output set at 56 degrees (LED display). I reckon the problem is the lack of adjustment on each rad, poor bugger on the top floor is loosing his share of heat to the over hot other 5. Can you buy replacement wheelhead caps in any of the sheds? Or is it another problem? The ideal solution would be to balance the heating system then fit TRVs. In this situation it's reasonable to pin the TRVs to a restricted range to prevent room taking on too much heat. An earlier version of which is to provide two lock shields so the inmates (oops I mean) users can tamper with the carefully and skillfully setup heating (yeah right). In practice all you are going to be allowed to do is to restrict the rads which are too hot. I would check that the radiator at the top is properly on at both ends. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html |
#4
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
We sell replacement caps at www.radcaps.co.uk
|
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Valve,Butterfly valve,Globe valve,Check valve,Ball valve,Plug valve,Marine valve,Gate valve,Flow control valve | UK diy | |||
Radiator valve caps? | UK diy | |||
Radiator Bleed Valve Replacement | UK diy | |||
Audio amp replacement filter caps ??? | Electronics Repair | |||
Radiator valve to radiator tail coupling | UK diy |