Default Loft insulation. Warm loft, colder bedrooms?

Hi,

I've recently moved into a 30 year old house which current has a warm
loft. The insulation is up against the roof with plasterboard keeping
it put. I understand that there needs to be a gap between the
insulation and the roof felt and I have no reason to suspect that this
wasn't done. There is no insulation in the loft floor. There are also
no vents in the eaves which I presume is correct when having a warm
loft.

My question is how much heat is lost from the bedrooms into the warm
loft? And is it very ineffecient to have a warm loft if I only store
things up there? We want to keep storing items in the loft but at the
same time keep the heat in the bedrooms. Should I insulate in the loft
floor as well or will this cause me problems with condensation, etc.
What is recommended for this situation? If I insulate the loft floor
do I need to remove the insulation in the roof and add some vents in
the eaves, therefore converting it into a cold loft? Could I just add
some 100mm/170mm thickness insulation in the loft floor to allow some
heat to stay in the room and allow some heat into the loft?

Many thanks in advance,
Paul.

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,447
Default Loft insulation. Warm loft, colder bedrooms?

On Oct 27, 2:38 pm, wrote:
Thus spake ) unto the assembled multitudes:





I've recently moved into a 30 year old house which current has a warm
loft. The insulation is up against the roof with plasterboard keeping
it put. I understand that there needs to be a gap between the
insulation and the roof felt and I have no reason to suspect that this
wasn't done. There is no insulation in the loft floor. There are also
no vents in the eaves which I presume is correct when having a warm
loft.
My question is how much heat is lost from the bedrooms into the warm
loft? And is it very ineffecient to have a warm loft if I only store
things up there? We want to keep storing items in the loft but at the
same time keep the heat in the bedrooms. Should I insulate in the loft
floor as well or will this cause me problems with condensation, etc.
What is recommended for this situation? If I insulate the loft floor
do I need to remove the insulation in the roof and add some vents in
the eaves, therefore converting it into a cold loft? Could I just add
some 100mm/170mm thickness insulation in the loft floor to allow some
heat to stay in the room and allow some heat into the loft?


I often think that fixing insulation under the roof itself is a waste of
time, though perhaps it might help keep the loft cooler on a hot summer's
day. To stop heat leaking into the loft from the rooms below, you need to
insulate the loft floor. I don't think you need remove the existing roof
insulation, but any heat getting into the loft is obviously wasting energy
and money.

I laid floorboards in my loft, having laid insulation between the joists
first and fixed wooden spacers on top of the joists to improve ventilation
between the insulation and the floorboards.

I've measured temperatures of just below 0C in my loft on a cold winter's
night, and as high as about 45C in high summer.

--
Andy Clews
University of Sussex
*** Remove DENTURES if replying by email ***- Hide quoted text -

- Show quoted text -


Based on practice here the OP seems to be on the right track. Would
add caveat that if you insulate ceiling it would be most desirable to
have a vapor barrier on the 'warm' side of the insulation. Some claim
that several coats of good 'oil' paint will act as an effective vapour
barrier! Not sure about that being as effective as a polyethylene
one?
Once you have the bedrooms insulated from the attic some warmth and
moisture will still escape up there and the attic being cooler than it
is now should be watched carefully for condensation. And it may be
necessary to to add or increase ventilation to avoid moisture, mould
and rot up there to contents and structure. Necessary in my opinion
even though the roof is insulated.
The rule here is that there should be 0.3% (that's 3 sq feet say for
every 1000 sq.feet of area) of ventilation in unheated attics and that
it must be arranged to allow cross-ventilation.
Eastern Canada; which is probably similar but somewaht cooler than say
Northern Scotland, although we are at the same latitude as Spain!.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Insulation on loft roof - insulation blankets...? Simon Hawthorne UK diy 10 April 18th 05 09:55 PM
Loft insulation? Mogweed UK diy 26 March 30th 05 07:19 PM
Loft insulation Broadback UK diy 3 October 24th 04 02:07 PM
Loft insulation David Hearn UK diy 26 November 10th 03 08:17 PM
Loft insulation Conrad Edwards UK diy 0 August 25th 03 09:57 PM


All times are GMT +1. The time now is 03:48 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"