TheScullster October 4th 07 09:31 AM

Worcester Green Star Flashing Blue Light
 
Hi all

Just wondering if this is anything to worry about.
Worcester 24Ri, one year old.
Intermittently the blue indicator light flashes (about once every second).
The fault lasts about 2 minutes and is seen to occur maybe once a week (but
then I'm not around to see it that much).
It's as though the system reaches a state that the boiler doesn't like
(maybe a flow issue when hw changes to ch - guessing) and it takes a short
while to stabilise.
When is occurred this morning I noticed some clicking, but it was not clear
whether this was an attempted boiler operation or just expansion noise.

Any suggestions/recommendations appreciated

TIA

Phil




John Stumbles October 4th 07 10:31 AM

Worcester Green Star Flashing Blue Light
 
On Thu, 04 Oct 2007 09:31:11 +0100, TheScullster wrote:

Any suggestions/recommendations appreciated


What does it say in the Installation and Servicing Manual which was
(by law) left with your boiler?

--
John Stumbles

Time flies like an arrow
Fruit flies like a banana
Tits like coconuts

TheScullster October 4th 07 12:31 PM

Worcester Green Star Flashing Blue Light
 

"John Stumbles" wrote

What does it say in the Installation and Servicing Manual which was
(by law) left with your boiler?


The install instructions give the following:

Fault - Volatile Lockout (sensor, fan or code plug)
Possible solution/check - Temp sensor 8000-20000ohm
- Wiring/connections to sensor
- Fan/cable/connections
- Code plug fitted

No idea what a code plug is!
Any thoughts on this lot?

Phil



geoff October 6th 07 01:03 AM

Worcester Green Star Flashing Blue Light
 
In message ,
TheScullster writes

"John Stumbles" wrote

What does it say in the Installation and Servicing Manual which was
(by law) left with your boiler?


The install instructions give the following:

Fault - Volatile Lockout (sensor, fan or code plug)
Possible solution/check - Temp sensor 8000-20000ohm
- Wiring/connections to sensor
- Fan/cable/connections
- Code plug fitted

No idea what a code plug is!
Any thoughts on this lot?

The code plug normally identifies to the processor which particular
appliance it's driving

I don't know on the greenstar

--
geoff