Fixing broken rad bleeder
Had to drain down CH system today to fit a new 3port valve, bloody annoying!
Anyhow I have a slim-line single convector rad in the hallway where the Square of the bleeder core is broken off, and the radiator construction is such that there is no room between the bleed valve itself and the body of the rad to get a socket on it to unscrew the whole unit. Any tips, or will I have to replace the whole rad?! On top of this, the whole thing has afew coats of paint on it! TIA Tim.. |
Fixing broken rad bleeder
"Tim.." wrote in message ... Had to drain down CH system today to fit a new 3port valve, bloody annoying! Anyhow I have a slim-line single convector rad in the hallway where the Square of the bleeder core is broken off, and the radiator construction is such that there is no room between the bleed valve itself and the body of the rad to get a socket on it to unscrew the whole unit. Any tips, or will I have to replace the whole rad?! On top of this, the whole thing has afew coats of paint on it! TIA Tim.. Drill through the centre with the right drill to fit the largest screw extractor yo can get in there. OR Just leave it and fit a new bleed screw in the other unused port on the radiator. Bob |
Fixing broken rad bleeder
In an earlier contribution to this discussion,
Tim.. wrote: Had to drain down CH system today to fit a new 3port valve, bloody annoying! Anyhow I have a slim-line single convector rad in the hallway where the Square of the bleeder core is broken off, and the radiator construction is such that there is no room between the bleed valve itself and the body of the rad to get a socket on it to unscrew the whole unit. Any tips, or will I have to replace the whole rad?! On top of this, the whole thing has afew coats of paint on it! TIA Tim.. I don't quite understand what you mean. presumably the manufacturer must have been able to get a socket on the bleed unit when screwing it in? Any chance of uploading a photo somewhere, and posting the URL here, so that we can see what you mean? The broken bleed screw pin is probably made of brass, so won't be too hard to drill. You may be able to drill a small hole through the middle, and use a small stud extractor to wind it out. I'm sure that you can buy replacement pins - or, at least, replacement bleed assemblies, and use the pin out of one. -- Cheers, Roger ______ Email address maintained for newsgroup use only, and not regularly monitored.. Messages sent to it may not be read for several weeks. PLEASE REPLY TO NEWSGROUP! |
Fixing broken rad bleeder
Bob Minchin wrote:
Just leave it and fit a new bleed screw in the other unused port on the radiator. Bob, you are a bloody genius! I have the same problem & that never occurred to me! Lateral thinking! -- Dave The Medway Handyman www.medwayhandyman.co.uk 01634 717930 07850 597257 |
Fixing broken rad bleeder
On Fri, 05 Jan 2007 21:46:28 +0000, Tim.. wrote:
Anyhow I have a slim-line single convector rad in the hallway where the Square of the bleeder core is broken off, and the radiator construction is such that there is no room between the bleed valve itself and the body of the rad to get a socket on it to unscrew the whole unit. You mean the bleed screw is recessed into a sort of shroud in the steel at the end of the rad? Maybe you could bodg^H^H^H^Himprovise an alternative bleed point at the other end of the rad (or the back surface at the top) by drilling & tapping another hole & fitting a brass screw with perhaps a tapering slot filed along its length so that it seals with a washer between the screw head and the metal. Or BES do some bleed valve assemblies which you might be able to fit. May just be easier to replace the rad if it's not too big & expensive & odd-sized. |
Fixing broken rad bleeder
"Bob Minchin" wrote in message ... "Tim.." wrote in message ... Had to drain down CH system today to fit a new 3port valve, bloody annoying! Anyhow I have a slim-line single convector rad in the hallway where the Square of the bleeder core is broken off, and the radiator construction is such that there is no room between the bleed valve itself and the body of the rad to get a socket on it to unscrew the whole unit. Any tips, or will I have to replace the whole rad?! On top of this, the whole thing has afew coats of paint on it! TIA Tim.. Drill through the centre with the right drill to fit the largest screw extractor yo can get in there. OR Just leave it and fit a new bleed screw in the other unused port on the radiator. Sadly , there isnt one. neither is there a lockshield valve either- just a single turn off. Tim.. |
Fixing broken rad bleeder
"John Stumbles" wrote in message .. . On Fri, 05 Jan 2007 21:46:28 +0000, Tim.. wrote: Anyhow I have a slim-line single convector rad in the hallway where the Square of the bleeder core is broken off, and the radiator construction is such that there is no room between the bleed valve itself and the body of the rad to get a socket on it to unscrew the whole unit. You mean the bleed screw is recessed into a sort of shroud in the steel at the end of the rad? Maybe you could bodg^H^H^H^Himprovise an alternative bleed point at the other end of the rad (or the back surface at the top) by drilling & tapping another hole & fitting a brass screw with perhaps a tapering slot filed along its length so that it seals with a washer between the screw head and the metal. Or BES do some bleed valve assemblies which you might be able to fit. May just be easier to replace the rad if it's not too big & expensive & odd-sized. I'll try to upload a photo in the morning. Many thanks, Tim.. |
Fixing broken rad bleeder
In an earlier contribution to this discussion,
The Medway Handyman wrote: Bob Minchin wrote: Just leave it and fit a new bleed screw in the other unused port on the radiator. Bob, you are a bloody genius! I have the same problem & that never occurred to me! Lateral thinking! You can certainly do that on rads which have a screwed blanking plug at the other end. But not all rads do - some are welded up solid at the opposite end from the bleed screw. I have a mixture of both types in my house! -- Cheers, Roger ______ Email address maintained for newsgroup use only, and not regularly monitored.. Messages sent to it may not be read for several weeks. PLEASE REPLY TO NEWSGROUP! |
Fixing broken rad bleeder
On Fri, 05 Jan 2007 22:35:57 +0000, Bob Minchin wrote:
"Tim.." wrote in message ... Had to drain down CH system today to fit a new 3port valve, bloody annoying! Anyhow I have a slim-line single convector rad in the hallway where the Square of the bleeder core is broken off, and the radiator construction is such that there is no room between the bleed valve itself and the body of the rad to get a socket on it to unscrew the whole unit. Any tips, or will I have to replace the whole rad?! On top of this, the whole thing has afew coats of paint on it! TIA Tim.. Drill through the centre with the right drill to fit the largest screw extractor yo can get in there. OR Just leave it and fit a new bleed screw in the other unused port on the radiator. I get the impression that this is a roll-top radiator not one with a hole at each corner. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards |
Fixing broken rad bleeder
I don't know whether I am missing something here or not, but why not just
use a radiator Allen key which is recessed on one end to unscrew the whole bleed valve unit. The end is drilled to fit over the actual bleed screw. http://www.plumbworld.co.uk/241-16143 or http://www.screwfix.com/app/sfd/cat/...99934&id=11467 or www.bes.ltd.uk part number 4846. HTH John |