DIYbanter

DIYbanter (https://www.diybanter.com/)
-   UK diy (https://www.diybanter.com/uk-diy/)
-   -   Towerstat RF (https://www.diybanter.com/uk-diy/187032-towerstat-rf.html)

yshaikh01 December 26th 06 02:44 PM

Towerstat RF
 
Hi

Does anybody have any experience in installing a Towerstat RF?
The manual specifies it has three connections, Live, Neutral and
Output.
How would this match up with a two wire low voltage connection on a
Combi Boiler?

Thanks


EricP December 26th 06 03:46 PM

Towerstat RF
 
On 26 Dec 2006 06:44:47 -0800, "yshaikh01"
wrote:

Hi

Does anybody have any experience in installing a Towerstat RF?
The manual specifies it has three connections, Live, Neutral and
Output.
How would this match up with a two wire low voltage connection on a
Combi Boiler?

Thanks


The Live and Neutral are for mains power from the boiler to power the
RF receiver and the Output and Neutral go to the boiler switch
connections where the link is removed to turn the boiler on and off.

EricP December 26th 06 03:50 PM

Towerstat RF
 
On 26 Dec 2006 06:44:47 -0800, "yshaikh01"
wrote:

Hi

Does anybody have any experience in installing a Towerstat RF?
The manual specifies it has three connections, Live, Neutral and
Output.
How would this match up with a two wire low voltage connection on a
Combi Boiler?

Thanks



This may give better definition.
http://www.tfc-group.co.uk/assets/gr...TT%20RF%20.pdf



Also don't forget to set the temp sensitivity and channels.

yshaikh01 December 26th 06 04:45 PM

Towerstat RF
 

EricP wrote:

On 26 Dec 2006 06:44:47 -0800, "yshaikh01"
wrote:

Hi

Does anybody have any experience in installing a Towerstat RF?
The manual specifies it has three connections, Live, Neutral and
Output.
How would this match up with a two wire low voltage connection on a
Combi Boiler?

Thanks


The Live and Neutral are for mains power from the boiler to power the
RF receiver and the Output and Neutral go to the boiler switch
connections where the link is removed to turn the boiler on and off.


According to the manual there is only one Neutral connection.


EricP December 26th 06 04:57 PM

Towerstat RF
 
On 26 Dec 2006 08:45:10 -0800, "yshaikh01"
wrote:


EricP wrote:

On 26 Dec 2006 06:44:47 -0800, "yshaikh01"
wrote:

Hi

Does anybody have any experience in installing a Towerstat RF?
The manual specifies it has three connections, Live, Neutral and
Output.
How would this match up with a two wire low voltage connection on a
Combi Boiler?

Thanks


The Live and Neutral are for mains power from the boiler to power the
RF receiver and the Output and Neutral go to the boiler switch
connections where the link is removed to turn the boiler on and off.


According to the manual there is only one Neutral connection.


I am sorry you received my posts, they were cancelled almost
immediately as my installation was not on your boiler.

Please disregard my replies.

Thanks and sorry.


All times are GMT +1. The time now is 08:17 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 DIYbanter