wrote:
Water flows freely from the loft down the pipe to the airing cupboard where there is a gate valve and the blockage is somewhere between the gate valve and the bath. I know this because I have taken the gate valve apart and the water is running up to that point and I have taken the tap apart and there is no water going to it. Which side of the gate valve did you take appart? I ask because these things have a habit of failing in just this way - the spindle breaks inside and they appear to open, but nothing gets through becasue the gate is no longer attached to the tap! -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |