Ariston Combi problem
Anybody know what the pressure gauge on an Ariston Combi should read?
Son has just bought his first house and the boiler gauge is at 3 bar and the water constantly drips from the overflow / expansion pipe when running. Also the fill loop valve appears to be constantly open. I am guessing the gauge should read between 0.5 and 1.5 bar, but it is only a guess. Many thanks -- Posted via Mailgate.ORG Server - http://www.Mailgate.ORG |
Ariston Combi problem
"Grumpy owd man" wrote in message news:52fcddbfd32ca97c42e2689eb3b1cbf3.115311@mygat e.mailgate.org... Anybody know what the pressure gauge on an Ariston Combi should read? Son has just bought his first house and the boiler gauge is at 3 bar and the water constantly drips from the overflow / expansion pipe when running. Also the fill loop valve appears to be constantly open. I am guessing the gauge should read between 0.5 and 1.5 bar, but it is only a guess. Many thanks 0.5 and 1 bar when cold. If the valve drips even when cold replace it. If it drips when hot then check the pressure vessel pressure or if the diaphragm is holed replace it. |
Ariston Combi problem
0.5 and 1 bar when cold. If the valve drips even when cold replace it. If it drips when hot then check the pressure vessel pressure or if the diaphragm is holed replace it. Ah!, I have not really explained it very well. the water is coming from a pipe which runs to the outside of the property if this make any difference. The drip is not internal -- Posted via Mailgate.ORG Server - http://www.Mailgate.ORG |
Ariston Combi problem
"Grumpy owd man" wrote in message news:3c270227b3833fa7756c53109fec9676.115311@mygat e.mailgate.org... 0.5 and 1 bar when cold. If the valve drips even when cold replace it. If it drips when hot then check the pressure vessel pressure or if the diaphragm is holed replace it. Ah!, I have not really explained it very well. the water is coming from a pipe which runs to the outside of the property if this make any difference. The drip is not internal Exactly. It is the pressure relief valve which is piped to outside. You will know if the diaphragm is holed as water comes out of the shrader valve. |
Ariston Combi problem
"Doctor Drivel" wrote in message
reenews.net Many thanks, i will have a look tomorrow -- Posted via Mailgate.ORG Server - http://www.Mailgate.ORG |
Ariston Combi problem
In message
ilgate.org, Grumpy owd man writes 0.5 and 1 bar when cold. If the valve drips even when cold replace it. If it drips when hot then check the pressure vessel pressure or if the diaphragm is holed replace it. Ah!, I have not really explained it very well. the water is coming from a pipe which runs to the outside of the property if this make any difference. The drip is not internal Pressure relief valve leaking ? find it, open it so it gives a good squirt there might be some crud which is preventing it from seating properly else, it's a drain down and replace it -- geoff |