Home |
Search |
Today's Posts |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
Posted to uk.d-i-y
|
|||
|
|||
Batten Spacing For Plasterboard
I'm using 2400 x 1200 12.5 Gyproc to board my bathroom walls on to
battens screwed to the walls. Should the vertical ones be at 400mm centres or would 600 mm be ok.?? Stuart |
#2
Posted to uk.d-i-y
|
|||
|
|||
Batten Spacing For Plasterboard
I'm using 2400 x 1200 12.5 Gyproc to board my bathroom walls on to
battens screwed to the walls. Should the vertical ones be at 400mm centres or would 600 mm be ok.?? Personally, I would use 400mm in case someone leans against the wall, especially if the wall is tiled, or in a frequently trafficed area (i.e. where people are squeezing past each other). Switch to 12mm WBP ply round the shower area. Christian. |
#3
Posted to uk.d-i-y
|
|||
|
|||
Batten Spacing For Plasterboard
On Mon, 13 Mar 2006 17:02:12 -0000, "Christian McArdle"
wrote: I'm using 2400 x 1200 12.5 Gyproc to board my bathroom walls on to battens screwed to the walls. Should the vertical ones be at 400mm centres or would 600 mm be ok.?? Personally, I would use 400mm in case someone leans against the wall, especially if the wall is tiled, or in a frequently trafficed area (i.e. where people are squeezing past each other). Switch to 12mm WBP ply round the shower area. Christian. Thx Christian ......400 it is ...It's not a busy bathroom but it is narrow and it's just me here but I can be a bit clumsy at times ..lol I'm going to use Aquapanel for the tiled area round the bath / shower. Stuart |
#4
Posted to uk.d-i-y
|
|||
|
|||
Batten Spacing For Plasterboard
I'm going to use Aquapanel for the tiled area round the bath / shower.
Yes, that's good stuff too. Christian. |
#5
Posted to uk.d-i-y
|
|||
|
|||
Batten Spacing For Plasterboard
On Mon, 13 Mar 2006 17:32:48 -0000, "Christian McArdle"
wrote: I'm going to use Aquapanel for the tiled area round the bath / shower. Yes, that's good stuff too. Christian. I should have asked .Do I need horizontal battens at the midway point as well or will the vertical ones suffice .? Stuart |
#6
Posted to uk.d-i-y
|
|||
|
|||
Batten Spacing For Plasterboard
Stuart wrote:
On Mon, 13 Mar 2006 17:32:48 -0000, "Christian McArdle" wrote: I'm going to use Aquapanel for the tiled area round the bath / shower. Yes, that's good stuff too. Christian. I should have asked .Do I need horizontal battens at the midway point as well or will the vertical ones suffice .? Stuart The thing with framing is you can do what you want, and the results vary widely. At one extreme, 2x2 uprights at 2' centres will make a wall, but plaster will pop cos it flexes too much, and it'll be as soundproof as paper. 2x4 every 16" plus noggins would be a very solid wall. You can go wherever you want between the 2. Noggins, they stiffen the wall up, make it more destructionproof, reduce sound transmission, and make it possible to attach things without them falling off. I'd always fit them, but you'll do what you want. Rockwool or similar also helps with sound resistance on interior walls and insulation on exterior. NT |
Reply |
Thread Tools | Search this Thread |