asalcedo November 14th 05 06:56 PM

compression fittings problem
 
My problem with compression fittings is that when I tighten the nut the pipe inside the nut also turns a little bit. This can be a big problem because it leads to loss of compression (and leaks) if there is a fixed nut in close proximity or to loss of geometry in the rest of the piping.

In the past I have been able to avoid it by holding the twisting pipe with a grip plier. The problem is that it requires "three hands" and leaves gripping marks on the pipe. Sometimes, to stop the twisting the gripping can lead to damage to the pipe.

I know I can use push fit fittings or soldered joints but I would like to know how to avoid this problem for future needs and for my particular situation now:

I am required to use compression fittings, with an existing compression service valve separated by 5cm of free pipe from a 90 degree compression fitting.

Thanks,

Antonio

Pet @ www.gymratz.co.uk ;¬) November 14th 05 11:31 PM

compression fittings problem
 
asalcedo wrote:

I am required to use compression fittings, with an existing compression
service valve separated by 5cm of free pipe from a 90 degree compression
fitting.


I would suggest that if the pipe is turning then you _may_ be
overtightening the fitting.

My most recent exploits with comp. fittings were sorted by the
application of a plumbers silicone sealer (Fernox LSX) around the olive
prior to assembly. It's holding out so far.

:¬)

--
http://gymratz.co.uk - Best Gym Equipment & Bodybuilding Supplements UK.
http://trade-price-supplements.co.uk - TRADE PRICED SUPPLEMENTS for ALL!
http://fitness-equipment-uk.com - UK's No.1 Fitness Equipment Suppliers.
http://gymratz.co.uk/hot-seat.htm - Live web-cam! (sometimes)

asalcedo November 15th 05 09:07 AM

Quote:

Originally Posted by Pet @ [url
www.gymratz.co.uk[/url] ;¬)]asalcedo wrote:

I am required to use compression fittings, with an existing compression
service valve separated by 5cm of free pipe from a 90 degree compression
fitting.


I would suggest that if the pipe is turning then you _may_ be
overtightening the fitting.

My most recent exploits with comp. fittings were sorted by the
application of a plumbers silicone sealer (Fernox LSX) around the olive
prior to assembly. It's holding out so far.

:¬)

--
http://gymratz.co.uk - Best Gym Equipment & Bodybuilding Supplements UK.
http://trade-price-supplements.co.uk - TRADE PRICED SUPPLEMENTS for ALL!
http://fitness-equipment-uk.com - UK's No.1 Fitness Equipment Suppliers.
http://gymratz.co.uk/hot-seat.htm - Live web-cam! (sometimes)

I am not overtightening. I am just tightening one turn after hand tightening.

I don't use any sealant or jointing compounds with compression fittings. According to the recommendations by the manufacturers, they are not needed and can, in the long term, jeopardize the fitting.

A clean olive and pipe does produce a joint without leaks, in my experience (save the turning pipe issue above)