JoeJoe October 9th 05 09:31 AM

Steel or concrete lintel?
 
I will soon be needing a lintel of around 2.5-2.7m.

My engineer hasn't finished his calculations yet, so I am not sure which one
I will need exactly, but it is meant to raplace a supporting wall in a
tenement flat removed in order to create an open plan kitchen.

In the past I used a concrete one, but the memory of having to carry it 2
floors up, and then position it at nearly 4m high (height of ceiling) is not
a pleasant one. Hence I decided to investigate the possibility of using a
steel one instead.

How do they compare in terms of:

1. Weight?
2. Price? (concrete one was ~ £30 last year IIRC)
3. Availability? (I can wait a few weeks).

Thanks a lot in advance.



Set Square October 9th 05 10:23 AM

Steel or concrete lintel?
 
In an earlier contribution to this discussion,
JoeJoe wrote:

I will soon be needing a lintel of around 2.5-2.7m.

My engineer hasn't finished his calculations yet, so I am not sure
which one I will need exactly, but it is meant to raplace a
supporting wall in a tenement flat removed in order to create an open
plan kitchen.

In the past I used a concrete one, but the memory of having to carry
it 2 floors up, and then position it at nearly 4m high (height of
ceiling) is not a pleasant one. Hence I decided to investigate the
possibility of using a steel one instead.

How do they compare in terms of:

1. Weight?
2. Price? (concrete one was ~ £30 last year IIRC)
3. Availability? (I can wait a few weeks).

Thanks a lot in advance.


Don't know about cost - but I would have thought that the obvious choice
would be an I-section RSJ - which is much stronger than a hollow steel
lintel of the type used over windows, and lighter than concrete. More or
less instantly available from any good steel stockist. You may need to get a
structural engineer to do some calculations to satisfy the BCO, but I'd be
surprised if it comes out bigger than 6" tall.

With a bit of luck, you'll be able to put it in the ceiling space - where it
will be hidden - with a continuous ceiling below it. If the ceiling joists
are at right-angles to it, you can cut them to fit into - and be supported
by - the I section (in which case the floor loading will need to be included
in the calculations).
--
Cheers,
Set Square
______
Please reply to newsgroup. Reply address is invalid.



Rick October 9th 05 04:17 PM

Steel or concrete lintel?
 
On Sun, 9 Oct 2005 09:31:54 +0100, "JoeJoe" wrote:

I will soon be needing a lintel of around 2.5-2.7m.

My engineer hasn't finished his calculations yet, so I am not sure which one
I will need exactly, but it is meant to raplace a supporting wall in a
tenement flat removed in order to create an open plan kitchen.

In the past I used a concrete one, but the memory of having to carry it 2
floors up, and then position it at nearly 4m high (height of ceiling) is not
a pleasant one. Hence I decided to investigate the possibility of using a
steel one instead.

How do they compare in terms of:

1. Weight?
2. Price? (concrete one was ~ £30 last year IIRC)
3. Availability? (I can wait a few weeks).

Thanks a lot in advance.


You should let your engineer say what he wants to see.

an 8 inch RSG intel is 25kg a meter, I got a 7.5 metre one into place
on my own, I used hand tools only.

RSJ's are cheep, catnec's are more expensive.

RSJ's are avalaible for collection from any decent steel stockholder,
delivery will depend upon what mood they are in.

Catnics, from any decent builders merchant.

I suspect you will be needing a whole lot more steel than you think.
You may need to put steel uprights in as well, if there is
insufficient walls left, and something for the uprights to rest on.

Rick


The Natural Philosopher October 13th 05 01:56 PM

Steel or concrete lintel?
 
JoeJoe wrote:

I will soon be needing a lintel of around 2.5-2.7m.

My engineer hasn't finished his calculations yet, so I am not sure which one
I will need exactly, but it is meant to raplace a supporting wall in a
tenement flat removed in order to create an open plan kitchen.

In the past I used a concrete one, but the memory of having to carry it 2
floors up, and then position it at nearly 4m high (height of ceiling) is not
a pleasant one. Hence I decided to investigate the possibility of using a
steel one instead.

How do they compare in terms of:

1. Weight?


Less for sure.

2. Price? (concrete one was ~ £30 last year IIRC)


Probably a bit more, but not much.

3. Availability? (I can wait a few weeks).


Should be possible - if you pick from a standard 'I' beam, its just a
question of cutting a bit off and delivering it..if you want a complete
frame - i.e. maybe square box section supports, and a welded on I beam
top..a few weeks is likley.

But I asseme its goind to be let into existing load bearing walls. DO be
aware though that as with any lintel, the total load of the wall above
no longer rests on continuous brickwork beneath - but on 2 points in the
outer walls. Sometimes extra strengthening is needed.