Hi All

Still trying to make some sense of the venting arrangements for my
drains in order to make the local Building Control bods happy and get
that all-important Completion Certificate.

So - I have a septic tank down at the bottom of the garden - and a
long-ish pipe run down to it. At the highest point there's an
earthenware 4" pipe which looks as if a 4" plastic vent pipe once went
straight up inside the bathroom and out through the roof.

Since then, a previous owner has removed the vent pipe and replaced it
with an air-admittance valve, at floor level.

Building Control want to see the AAV removed and a 'real' vent open to
the air reinstated.

Because it's in a very obvious position (in an alcove with the
washbasin / large mirror etc) I'm keen to make the whole thing look as
unobtrusive as possible. Apparently I can go from 4" to 3" pipe once
I'm above the level of the basin overflow - this will help a little
with the appearance and getting the inevitable boxing-in to be as
close to the wall as poss .

Because it's not easy catching up with the Building Bods as they're
apparently understaffed and running about on sites all day - I'm
asking here g

So - a few questions :-

a) Is it possible to get an offset adapter to go from 4" to 3" -
"in-line" ?
b) Am I going to have problems obtaining 3" pipe & fittings ?
c) Can the pipe pass out through the gable end of the bungalow (I know
about the restrictions re opening windows) - or does it have to go out
through the roof ?
d) If it goes through the roof - is this just a matter of removing a
concrete tile and fitting one of those
'ali-sheets-with-a-rubber-collar' efforts - does the ali sheet replace
the tile ??

Many thanks in advance
Adrian
Suffolk UK
======return email munged=================
take out the papers and the trash to reply
  #3   Report Post  
Adrian Brentnall
 
Posts: n/a
Default

Hi Stuart

On Fri, 30 Sep 2005 09:39:44 +0100, Lurch
wrote:

On Fri, 30 Sep 2005 08:37:54 +0100, Adrian Brentnall adrian-the
papers and the scrawled:

a) Is it possible to get an offset adapter to go from 4" to 3" -
"in-line" ?


Yep. All the 4" - 3" adapters I've seen have been offset, whether this
is just conicidence or a standard fitting I have no idea but they are
available.


great !


b) Am I going to have problems obtaining 3" pipe & fittings ?


Shouldn't have thought so, try a local plumbers merchants and see what
they say. If their answer is "yes sir, we keep 3" pipe and fittings in
stock and on the shelf" then job's a good 'un.


I'll do some phoning....

c) Can the pipe pass out through the gable end of the bungalow (I know
about the restrictions re opening windows) - or does it have to go out
through the roof ?


Pass.


Hmmm - I'm just thinking that it'd look tidier if we came out through
the gable - but it would also add about 12ft to the pipe-run - so
maybe the 'straight through the roof' option is a simpler
proposition....


d) If it goes through the roof - is this just a matter of removing a
concrete tile and fitting one of those
'ali-sheets-with-a-rubber-collar' efforts - does the ali sheet replace
the tile ??

Pretty much, I did the same here for the boiler flue and it was just a
case of remove tile, cut felt, insert flue, slip collar over and
fashion to approximate tile shape. There may have been some silicone
involved although I don't think that's strictly neccesary.


Sounds straight-forward enough. By Murphy's 3rd law of DIY the hole in
the flashing slate won't correspond with the position of the hole in
the ceiling - but I guess a couple of 3" elbows will sort that one....

All sounds pretty do-able - thanks for the comments...

Adrian
======return email munged=================
take out the papers and the trash to reply
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Are push fit plumbing fittings any good? Steve UK diy 75 September 3rd 05 02:56 PM
Cast Iron Soil Pipe Advice Stephen UK diy 2 May 4th 05 08:18 AM
Fitting Soil Pipe to Oversize Coupling [email protected] UK diy 6 April 26th 05 09:12 AM
Any soil pipe experts? Pecanfan UK diy 15 January 21st 05 04:09 PM
undoing cast iron soil pipe joint Alasdair UK diy 8 February 2nd 04 08:17 AM


All times are GMT +1. The time now is 05:42 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"