Dave April 1st 05 02:15 PM

What's the best way to lag pipes?
 
I've finally finished installing the new heating and DHW system (with
some help) but now I need to insulate all the pipework. Most of the
downstairs ceilings are down so I can get to the pipes easily; the
boiler, cylinder, zone valves and DHW circulation pump are all in the
back of the garage.
What's the best and most economical way to insulate the pipes?
I've seen the lengths of semi-rigid foam sleeve in the sheds but these
ar not going to be any good on the bends (and are not cheap).

Dave S

[news] April 1st 05 02:23 PM

Dave wrote:
I've finally finished installing the new heating and DHW system (with
some help) but now I need to insulate all the pipework. Most of the
downstairs ceilings are down so I can get to the pipes easily; the
boiler, cylinder, zone valves and DHW circulation pump are all in the
back of the garage.
What's the best and most economical way to insulate the pipes?


foam pipe lagging. I only did mine in areas which may have been
vulnerable to frost, against an external wall, for example.

I've seen the lengths of semi-rigid foam sleeve in the sheds but these
ar not going to be any good on the bends


cable tie them on.

(and are not cheap).


cost/benefit analysis, work out the cost and payback time. your call



RT







Andrew Gabriel April 1st 05 02:58 PM

In article ,
Dave writes:
I've finally finished installing the new heating and DHW system (with
some help) but now I need to insulate all the pipework. Most of the
downstairs ceilings are down so I can get to the pipes easily; the
boiler, cylinder, zone valves and DHW circulation pump are all in the
back of the garage.
What's the best and most economical way to insulate the pipes?
I've seen the lengths of semi-rigid foam sleeve in the sheds but these
ar not going to be any good on the bends (and are not cheap).


The best way is to feed the pipe through them as you install it,
so you don't have to split the foam sleeve afterwards. If you
do split it, it has a tendancy over time to open up at the split.
You can get some plastic staple like things you push in along the
split to stop it doing this, but I don't know how effective they
are. It does follow swept bends OK (at least when you don't split
it). I tended to cut the pieces slightly too long so that it is
in compression when installed. I see lots of installations where
it's shrunk leaving bits of pipe exposed, and mine hasn't done
this (yet, anyway).

For central heating, I believe it is only required to insulate
where the pipework passes through unheated areas, like under a
suspended ground floor, but not for example between a floor and
ceiling of two heated areas. I also insulated it where any
electricity cables were in close proximity, but that was more
to protect the cables from heat. This can also be a good idea
where it's near a cold water supply pipe, so you don't turn on
the cold tap and find it runs warm for several seconds.
Part L also requires insulation of the pipes connecting to the
hot water cylinder, if you have one.

I bought my insulation from Wickes who had it going cheap at the
time as part of one of the energy saving initiatives. I believe
the foam you need is the type with the wall thickness same as the
pipe diameter. There is some much thicker stuff too, but thats
rather more for preventing outdoor and loft cold water pipes
freezing in winter. You might consider that for the pipework in
your garage if it's not heated, but ISTR it was much more expensive.

--
Andrew Gabriel

John Stumbles April 1st 05 04:05 PM

Dave wrote:
I've finally finished installing the new heating and DHW system (with
some help) but now I need to insulate all the pipework. Most of the
downstairs ceilings are down so I can get to the pipes easily; the
boiler, cylinder, zone valves and DHW circulation pump are all in the
back of the garage.
What's the best and most economical way to insulate the pipes?
I've seen the lengths of semi-rigid foam sleeve in the sheds but these
ar not going to be any good on the bends (and are not cheap).


You can get a sort of metallised bubble wrap in about 50mm width for
pipe lagging, from the usual online suspects, but it's a bit pricey.
However Wickes (and no doubt others) do the same(?) stuff in about 600mm
width which would probably be cheaper and possibly easier to use.

Rob Morley April 1st 05 04:41 PM

In article , "Dave"
says...
I've finally finished installing the new heating and DHW system (with
some help) but now I need to insulate all the pipework. Most of the
downstairs ceilings are down so I can get to the pipes easily; the
boiler, cylinder, zone valves and DHW circulation pump are all in the
back of the garage.
What's the best and most economical way to insulate the pipes?
I've seen the lengths of semi-rigid foam sleeve in the sheds but these
ar not going to be any good on the bends (and are not cheap).

Put the foam on a straight bit of pipe near the curve, glue it
together, then slide it over the bend when the glue has dried.
If it's an elbow rather than a bend you can mitre the sleeve.

Christian McArdle April 1st 05 06:01 PM

I've seen the lengths of semi-rigid foam sleeve in the sheds but these
ar not going to be any good on the bends (and are not cheap).


There's more expensive flexible stuff. I'd use that for tightly flowed bends
and use the cheaper semi-rigid stuff for straights, lightly flowed bends and
elbows.

Christian.



Pete C April 1st 05 06:05 PM

On Fri, 1 Apr 2005 13:15:29 +0000 (UTC), Dave
wrote:

I've finally finished installing the new heating and DHW system (with
some help) but now I need to insulate all the pipework. Most of the
downstairs ceilings are down so I can get to the pipes easily; the
boiler, cylinder, zone valves and DHW circulation pump are all in the
back of the garage.
What's the best and most economical way to insulate the pipes?
I've seen the lengths of semi-rigid foam sleeve in the sheds but these
ar not going to be any good on the bends (and are not cheap).


Hi,

What sort of per m price were they charging, and what dia/thickness?

cheers,
Pete.

The Natural Philosopher April 2nd 05 12:38 AM

Dave wrote:

I've finally finished installing the new heating and DHW system (with
some help) but now I need to insulate all the pipework. Most of the
downstairs ceilings are down so I can get to the pipes easily; the
boiler, cylinder, zone valves and DHW circulation pump are all in the
back of the garage.
What's the best and most economical way to insulate the pipes?
I've seen the lengths of semi-rigid foam sleeve in the sheds but these
ar not going to be any good on the bends (and are not cheap).


Bends you can bend the foam and wrap with duct tape etc.

No real need to insulate inside 'warm spaces'.

In studowork, pack glass fibre rockwool all around.

Dave S