Default Power feed problem


I have a Central Machinery (HF) power feed on the X axis of my RF45
clone mill and it's acting weird . Works fine on the fast move button
but the speed settings are messed up . It doesn't start turning until I
get to "2" on the dial and by the time it's up to 3 it's going full
speed . It just started yhis , today is the firt=st time I've seen this
.. When it was working right it would start before I got up to one and
would ramp up perfectly as i turned it up .
Am I looking at a bad rheostat or maybe just dirty ? Should be clean
, that unit is sealed up tight - but ya never know .
--
Snag
Illegitimi non
carborundum
  #2   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 138
Default Power feed problem

That sounds like a bad SCR.
  #3   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 257
Default Power feed problem

On 7/13/2020 5:25 PM, Michael Terrell wrote:
That sounds like a bad SCR.


OK , I don't know a lot about SCR's , but I have some experience with
electronics . How do I test it ? I was planning on starting by checking
the resistance of both sides of the control pot ... but I have no idea
how to test an SCR .
--
Snag
Illegitimi non
carborundum
  #4   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 138
Default Power feed problem

The easiest is to just replace it. Use the same part number. The sensitivity varies all over the map, with different types. They are usually cheap, and a lot cheaper than a test fixture.
  #5   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 5,888
Default Power feed problem

"Snag" wrote in message ...

On 7/13/2020 5:25 PM, Michael Terrell wrote:
That sounds like a bad SCR.


OK , I don't know a lot about SCR's , but I have some experience with
electronics . How do I test it ? I was planning on starting by checking
the resistance of both sides of the control pot ... but I have no idea
how to test an SCR .
--
Snag
Illegitimi non
carborundum

===========================

A thorough test requires lab equipment to measure Off-state leakage current
at full working voltage and the minimum gate triggering current, but a
functional check is simple:
https://www.circuitstoday.com/how-to-test-an-scr

I'd suspect an intermittent pot wiper contact.



  #6   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 3,984
Default Power feed problem

On Tuesday, July 14, 2020 at 5:57:09 AM UTC-4, Jim Wilkins wrote:
"Snag" wrote in message ...

On 7/13/2020 5:25 PM, Michael Terrell wrote:
That sounds like a bad SCR.


OK , I don't know a lot about SCR's , but I have some experience with
electronics . How do I test it ? I was planning on starting by checking
the resistance of both sides of the control pot ... but I have no idea
how to test an SCR .
--
Snag
Illegitimi non
carborundum

===========================

A thorough test requires lab equipment to measure Off-state leakage current
at full working voltage and the minimum gate triggering current, but a
functional check is simple:
https://www.circuitstoday.com/how-to-test-an-scr

I'd suspect an intermittent pot wiper contact.


+1

If turns out to be the SCR, let me know. I have some SCR's I salvaged from the scrap yard. I forget the specs, but they are good for about 1000 amps.

Dan
  #7   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 115
Default Power feed problem

Jim Wilkins wrote:

OK , I don't know a lot about SCR's , but I have some experience with
electronics . How do I test it ? I was planning on starting by checking
the resistance of both sides of the control pot ... but I have no idea
how to test an SCR .


In principle, it's easy 8-). First, test it like a diode,
however if it conducts either way it's faulty.

Then test it forward biased and momentarily connect gate to anode.
It should start conducting and stay that way.

There are two traps in this: One is that an SCR generally needs at
least two forward diode drops, 1.4 volts, to work at all. The other
is that "latching" the SCR on requires some minimum current, maybe
1% or less of running current. Far more than a normal diode tester
provides. A car battery and taillight bulb would probably work.

HTH,

bob prohaska



  #8   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 10,399
Default Power feed problem

On Mon, 13 Jul 2020 17:18:17 -0500, Snag wrote:


I have a Central Machinery (HF) power feed on the X axis of my RF45
clone mill and it's acting weird . Works fine on the fast move button
but the speed settings are messed up . It doesn't start turning until I
get to "2" on the dial and by the time it's up to 3 it's going full
speed . It just started yhis , today is the firt=st time I've seen this
. When it was working right it would start before I got up to one and
would ramp up perfectly as i turned it up .
Am I looking at a bad rheostat or maybe just dirty ? Should be clean
, that unit is sealed up tight - but ya never know .


Got a bad pot ..rheostat.

Open and spritz the pot with cleaner. However..it may be bad..so check
with any online sorce for new potentiometer.

Gunner
__

"Journalists are extremely rare and shouldn’t be harmed, but propagandists are everywhere and should be hunted for sport"

Yeah..with no bag limit.




--
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
B`port power feed gear box part needed???? Craig Suslosky Metalworking 0 February 24th 04 04:39 AM
power shower feed manoman UK diy 12 November 16th 03 09:24 PM
B`port power table feed ???? Craig Suslosky Metalworking 1 September 25th 03 04:27 AM
Power to loft. Spur of 60A shower feed? Will Cooke UK diy 1 August 5th 03 12:15 AM
Help Installing Align Power Feed on Bridgeport Please? Wally Blackburn Metalworking 0 July 13th 03 02:28 PM


All times are GMT +1. The time now is 03:58 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"