Terry Coombs[_2_] October 8th 18 08:45 PM

Hydraulics related question
 
Β*Well the log splitter is mostly metal too ... ennyway , I have a minor
but irritating problem with the actuator valve . Pull to split and it
goes great , pull the handle back to retract and it works great . As
long as you hold it back . There's an internal detent there that's
supposed to hold the handle in the retract position until the ram
bottoms out , and it's not holding . Directly opposite the valve piston
on the other end is a formed sheet metal cup device with a socket head
cap screw sticking out , it has a jam nut to hold it adjusted ... I
THINK this is where I'd adjust tension on that detent , but then again ,
I have zero experience with hydraulic valves .

--
Snag
Yes , I'm old
and crochety - and armed .
Get outta my woods !


?B?UE02NUPimpvihpAg4pWsIPCdkbTwnZKK8J2SiPCdkonwnZKV8J2SmiDwnZG+?=?B?8J2SgvCdko/wnZKP8J October 8th 18 10:45 PM

Hydraulics related question
 
Terry Coombs wrote on 10/8/2018 3:45 PM:
Β*Well the log splitter is mostly metal too ... ennyway , I have a
minor but irritating problem with the actuator valve . Pull to split
and it goes great , pull the handle back to retract and it works great
. As long as you hold it back . There's an internal detent there
that's supposed to hold the handle in the retract position until the
ram bottoms out , and it's not holding . Directly opposite the valve
piston on the other end is a formed sheet metal cup device with a
socket head cap screw sticking out , it has a jam nut to hold it
adjusted ... I THINK this is where I'd adjust tension on that detent ,
but then again , I have zero experience with hydraulic valves .


See if this helps:

https://www.drpower.com/_drp/downloads/support/manuals/wds/279321E_Horizonta_Vertical_Log_Splitter_S-O_Manual_160606.pdf

page 26 in the PDF:

Adjusting the Handle Return Lever

A Handle Return Lever is attached to the Valve Bracket to manually stop
the Wedge when it is fully retracted.Β* The Lever may need to be adjusted
if:

- The Wedge is not retracting fully.

- The Engine stalls and the Actuator Handle stays in the retract
position with the Wedge is fully retracted.

1. Loosen the Jam Nut.

2. Adjust the Bolt.

Screw Bolt into the Return Lever if the Operator lever is being pushed
forward before fully retracting.

Unscrew the Bolt from the Return Lever if the Operator lever is not
being disengaged and the Engine is stalling.

3. When finished, hold the Bolt with the Wrench as you tighten the Jam
Nut against the Lever using a Wrench.Β* Test and readjust as needed.







Terry Coombs[_2_] October 8th 18 11:43 PM

Hydraulics related question
 
On 10/8/2018 4:45 PM, PM65Cš›† •¬ π‘΄π’Šπ’ˆπ’‰π’•π’š 𝑾𝒂𝒏𝒏𝒂𝒃𝒆 •¬ †’š›gAccu wrote:
Terry Coombs wrote on 10/8/2018 3:45 PM:
Β*Well the log splitter is mostly metal too ... ennyway , I have a
minor but irritating problem with the actuator valve . Pull to split
and it goes great , pull the handle back to retract and it works
great . As long as you hold it back . There's an internal detent
there that's supposed to hold the handle in the retract position
until the ram bottoms out , and it's not holding . Directly opposite
the valve piston on the other end is a formed sheet metal cup device
with a socket head cap screw sticking out , it has a jam nut to hold
it adjusted ... I THINK this is where I'd adjust tension on that
detent , but then again , I have zero experience with hydraulic valves .


See if this helps:

https://www.drpower.com/_drp/downloads/support/manuals/wds/279321E_Horizonta_Vertical_Log_Splitter_S-O_Manual_160606.pdf


page 26 in the PDF:

Adjusting the Handle Return Lever

A Handle Return Lever is attached to the Valve Bracket to manually
stop the Wedge when it is fully retracted.Β* The Lever may need to be
adjusted if:

- The Wedge is not retracting fully.

- The Engine stalls and the Actuator Handle stays in the retract
position with the Wedge is fully retracted.

1. Loosen the Jam Nut.

2. Adjust the Bolt.

Screw Bolt into the Return Lever if the Operator lever is being pushed
forward before fully retracting.

Unscrew the Bolt from the Return Lever if the Operator lever is not
being disengaged and the Engine is stalling.

3. When finished, hold the Bolt with the Wrench as you tighten the Jam
Nut against the Lever using a Wrench.Β* Test and readjust as needed.






Β* Thank you !

--
Snag
Yes , I'm old
and crochety - and armed .
Get outta my woods !



All times are GMT +1. The time now is 03:55 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 DIYbanter