freak September 26th 16 10:48 PM

fake air compressor aftercooler?
 
I broke the aftercooler off of my air compressor the other day. It's a 20cfm import aluminum pump with a cast iron jug. While contemplating fixes I thought about the usefulness of this aftercooler. The point of the aftercooler is to condense moisture out of the air and keep it out of the tank. The way this is designed, the moisture (even if it had the capacity to condense any moisture which I doubt) has no where to go. Any moisture trapped in the first bend would eventually turn back into vapor and make it to the tank. I think this aftercooler is just there for looks. It's just to make the compressor seem more valuable to uneducated buyers (which I guess I was). Opinions?

Link to aftercooler image...

http://imgur.com/a/nGuWm

Pete Keillor[_2_] September 26th 16 11:14 PM

fake air compressor aftercooler?
 
On Mon, 26 Sep 2016 14:48:33 -0700, freak wrote:

I broke the aftercooler off of my air compressor the other day. It's a
20cfm import aluminum pump with a cast iron jug. While contemplating
fixes I thought about the usefulness of this aftercooler. The point of
the aftercooler is to condense moisture out of the air and keep it out
of the tank. The way this is designed, the moisture (even if it had the
capacity to condense any moisture which I doubt) has no where to go.
Any moisture trapped in the first bend would eventually turn back into
vapor and make it to the tank. I think this aftercooler is just there
for looks. It's just to make the compressor seem more valuable to
uneducated buyers (which I guess I was). Opinions?

Link to aftercooler image...

http://imgur.com/a/nGuWm


An INTERcooler is useful in a two stage compressor. By getting rid of
some of the heat of compression allows the 2nd stage to do more work.

Pete Keillor

freak September 26th 16 11:21 PM

fake air compressor aftercooler?
 
On Monday, September 26, 2016 at 6:14:31 PM UTC-4, Pete Keillor wrote:
On Mon, 26 Sep 2016 14:48:33 -0700, freak wrote:

I broke the aftercooler off of my air compressor the other day. It's a
20cfm import aluminum pump with a cast iron jug. While contemplating
fixes I thought about the usefulness of this aftercooler. The point of
the aftercooler is to condense moisture out of the air and keep it out
of the tank. The way this is designed, the moisture (even if it had the
capacity to condense any moisture which I doubt) has no where to go.
Any moisture trapped in the first bend would eventually turn back into
vapor and make it to the tank. I think this aftercooler is just there
for looks. It's just to make the compressor seem more valuable to
uneducated buyers (which I guess I was). Opinions?

Link to aftercooler image...

http://imgur.com/a/nGuWm


An INTERcooler is useful in a two stage compressor. By getting rid of
some of the heat of compression allows the 2nd stage to do more work.

Pete Keillor



Nice point... but this is the aftercooler.

Gunner Asch[_6_] September 27th 16 08:38 AM

fake air compressor aftercooler?
 
On Mon, 26 Sep 2016 14:48:33 -0700 (PDT), freak
wrote:

I broke the aftercooler off of my air compressor the other day. It's a 20cfm import aluminum pump with a cast iron jug. While contemplating fixes I thought about the usefulness of this aftercooler. The point of the aftercooler is to condense moisture out of the air and keep it out of the tank. The way this is designed, the moisture (even if it had the capacity to condense any moisture which I doubt) has no where to go. Any moisture trapped in the first bend would eventually turn back into vapor and make it to the tank. I think this aftercooler is just there for looks. It's just to make the compressor seem more valuable to uneducated buyers (which I guess I was). Opinions?

Link to aftercooler image...

http://imgur.com/a/nGuWm



They actually do chill the air enough to condense the water. How well
that piece of crap ....er...compressor does it...remains to be seen.


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus


freak September 27th 16 10:21 PM

fake air compressor aftercooler?
 
On Tuesday, September 27, 2016 at 3:38:35 AM UTC-4, Gunner Asch wrote:
On Mon, 26 Sep 2016 14:48:33 -0700 (PDT), freak

I broke the aftercooler off of my air compressor the other day. It's a 20cfm import aluminum pump with a cast iron jug. While contemplating fixes I thought about the usefulness of this aftercooler. The point of the aftercooler is to condense moisture out of the air and keep it out of the tank. The way this is designed, the moisture (even if it had the capacity to condense any moisture which I doubt) has no where to go. Any moisture trapped in the first bend would eventually turn back into vapor and make it to the tank. I think this aftercooler is just there for looks. It's just to make the compressor seem more valuable to uneducated buyers (which I guess I was). Opinions?

Link to aftercooler image...

http://imgur.com/a/nGuWm



They actually do chill the air enough to condense the water. How well
that piece of crap ....er...compressor does it...remains to be seen.



You missed the point gunner... say it removes moisture with great efficiency,.. Where is the moisture going to go? It can only go to the tank. So the aftercooler is pointless IMHO.

Larry Jaques[_4_] September 27th 16 11:26 PM

fake air compressor aftercooler?
 
On Tue, 27 Sep 2016 14:21:18 -0700 (PDT), freak
wrote:

On Tuesday, September 27, 2016 at 3:38:35 AM UTC-4, Gunner Asch wrote:
On Mon, 26 Sep 2016 14:48:33 -0700 (PDT), freak

I broke the aftercooler off of my air compressor the other day. It's a 20cfm import aluminum pump with a cast iron jug. While contemplating fixes I thought about the usefulness of this aftercooler. The point of the aftercooler is to condense moisture out of the air and keep it out of the tank. The way this is designed, the moisture (even if it had the capacity to condense any moisture which I doubt) has no where to go. Any moisture trapped in the first bend would eventually turn back into vapor and make it to the tank. I think this aftercooler is just there for looks. It's just to make the compressor seem more valuable to uneducated buyers (which I guess I was). Opinions?

Link to aftercooler image...

http://imgur.com/a/nGuWm



They actually do chill the air enough to condense the water. How well
that piece of crap ....er...compressor does it...remains to be seen.



You missed the point gunner... say it removes moisture with great efficiency,.. Where is the moisture going to go? It can only go to the tank. So the aftercooler is pointless IMHO.


Don't spendy units auto-drain after the compressor tops off? (or have
dual purpose unloaders) Or do they have reservoirs where the collected
moisture is retained? If not, why not? (Entrepreneurs, make your
million here!)


For the recent fishermen, here's a laugh:
http://newatlas.com/melloship-hammock-boat/45625/

--
The goal to strive for is a poor government but a rich people.

--Andrew Johnson

freak September 27th 16 11:51 PM

fake air compressor aftercooler?
 
On Tuesday, September 27, 2016 at 6:26:48 PM UTC-4, Larry Jaques wrote:
On Tue, 27 Sep 2016 14:21:18 -0700 (PDT), freak



On Tuesday, September 27, 2016 at 3:38:35 AM UTC-4, Gunner Asch wrote:
On Mon, 26 Sep 2016 14:48:33 -0700 (PDT), freak

I broke the aftercooler off of my air compressor the other day. It's a 20cfm import aluminum pump with a cast iron jug. While contemplating fixes I thought about the usefulness of this aftercooler. The point of the aftercooler is to condense moisture out of the air and keep it out of the tank. The way this is designed, the moisture (even if it had the capacity to condense any moisture which I doubt) has no where to go. Any moisture trapped in the first bend would eventually turn back into vapor and make it to the tank. I think this aftercooler is just there for looks. It's just to make the compressor seem more valuable to uneducated buyers (which I guess I was). Opinions?

Link to aftercooler image...

http://imgur.com/a/nGuWm


They actually do chill the air enough to condense the water. How well
that piece of crap ....er...compressor does it...remains to be seen.



You missed the point gunner... say it removes moisture with great efficiency,.. Where is the moisture going to go? It can only go to the tank. So the aftercooler is pointless IMHO.


Don't spendy units auto-drain after the compressor tops off? (or have
dual purpose unloaders) Or do they have reservoirs where the collected
moisture is retained? If not, why not? (Entrepreneurs, make your
million here!)



Sure... I have an auto drain on mine.

Gunner Asch[_6_] September 28th 16 03:57 AM

fake air compressor aftercooler?
 
On Tue, 27 Sep 2016 14:21:18 -0700 (PDT), freak
wrote:

On Tuesday, September 27, 2016 at 3:38:35 AM UTC-4, Gunner Asch wrote:
On Mon, 26 Sep 2016 14:48:33 -0700 (PDT), freak

I broke the aftercooler off of my air compressor the other day. It's a 20cfm import aluminum pump with a cast iron jug. While contemplating fixes I thought about the usefulness of this aftercooler. The point of the aftercooler is to condense moisture out of the air and keep it out of the tank. The way this is designed, the moisture (even if it had the capacity to condense any moisture which I doubt) has no where to go. Any moisture trapped in the first bend would eventually turn back into vapor and make it to the tank. I think this aftercooler is just there for looks. It's just to make the compressor seem more valuable to uneducated buyers (which I guess I was). Opinions?

Link to aftercooler image...

http://imgur.com/a/nGuWm



They actually do chill the air enough to condense the water. How well
that piece of crap ....er...compressor does it...remains to be seen.



You missed the point gunner... say it removes moisture with great efficiency,.. Where is the moisture going to go? It can only go to the tank. So the aftercooler is pointless IMHO.



Yes..it condenses and runs into the tank. Which you are supposed to
drain every now and then. In some places..daily.

Sure beats having that water IN the air and headed for your paint
gun...no?


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus


Randy333 October 12th 16 06:11 PM

fake air compressor aftercooler?
 
On Tue, 27 Sep 2016 19:57:54 -0700, Gunner Asch
wrote:

On Tue, 27 Sep 2016 14:21:18 -0700 (PDT), freak
wrote:

On Tuesday, September 27, 2016 at 3:38:35 AM UTC-4, Gunner Asch wrote:
On Mon, 26 Sep 2016 14:48:33 -0700 (PDT), freak

I broke the aftercooler off of my air compressor the other day. It's a 20cfm import aluminum pump with a cast iron jug. While contemplating fixes I thought about the usefulness of this aftercooler. The point of the aftercooler is to condense moisture out of the air and keep it out of the tank. The way this is designed, the moisture (even if it had the capacity to condense any moisture which I doubt) has no where to go. Any moisture trapped in the first bend would eventually turn back into vapor and make it to the tank. I think this aftercooler is just there for looks. It's just to make the compressor seem more valuable to uneducated buyers (which I guess I was). Opinions?

Link to aftercooler image...

http://imgur.com/a/nGuWm


They actually do chill the air enough to condense the water. How well
that piece of crap ....er...compressor does it...remains to be seen.



You missed the point gunner... say it removes moisture with great efficiency,.. Where is the moisture going to go? It can only go to the tank. So the aftercooler is pointless IMHO.



Yes..it condenses and runs into the tank. Which you are supposed to
drain every now and then. In some places..daily.

Sure beats having that water IN the air and headed for your paint
gun...no?


BINGO!

And hot air in the tank might just take some water out of the tank and
carry it along for the ride.