Grant Erwin December 1st 05 06:16 PM

flowmeter plumbing - will this work?
 
I get tired of asking these "will this work" questions but where I live I'd have
to drive 40 miles to ask this question of a knowledgeable local source. Anyway,
I have a surplus regulator which I've used for some time on a CO2 tank (plumbed
in via an adapter) but which has a connector which threads correctly to e.g. an
argon tank. It is a pressure regulator, though, not a flowmeter, and I want to
use this in GMAW. So I got an Airco flowmeter, removed it's weird POL-like
connector, bushed down the 1/4NPT to 1/8NPTF and put a 2½" 1/8" nipple, and just
threaded that into the flowmeter:
http://www.tinyisland.com/images/temp/flowmeter.jpg

I have never seen a flowmeter cobbled onto the end of a regulator like this. I'm
almost 100% ignorant in this area. Will this work correctly for me? There are
two knobs, one sets the pressure on the regulator, the other on the flowmeter
must be a needle valve, right? So I'd set the regulator to 30 psi on the gauge
and then adjust the knob on the flowmeter to get my desired cubic feet per hour
of argon?

Grant Erwin
Kirkland, Washington

Ned Simmons December 1st 05 06:31 PM

flowmeter plumbing - will this work?
 
In article ,
says...
I get tired of asking these "will this work" questions but where I live I'd have
to drive 40 miles to ask this question of a knowledgeable local source. Anyway,
I have a surplus regulator which I've used for some time on a CO2 tank (plumbed
in via an adapter) but which has a connector which threads correctly to e.g. an
argon tank. It is a pressure regulator, though, not a flowmeter, and I want to
use this in GMAW. So I got an Airco flowmeter, removed it's weird POL-like
connector, bushed down the 1/4NPT to 1/8NPTF and put a 2½" 1/8" nipple, and just
threaded that into the flowmeter:
http://www.tinyisland.com/images/temp/flowmeter.jpg

I have never seen a flowmeter cobbled onto the end of a regulator like this. I'm
almost 100% ignorant in this area. Will this work correctly for me? There are
two knobs, one sets the pressure on the regulator, the other on the flowmeter
must be a needle valve, right? So I'd set the regulator to 30 psi on the gauge
and then adjust the knob on the flowmeter to get my desired cubic feet per hour
of argon?


Why it looks just like my scabbed together TIG flowmeter,
except I have a tee between the regulator and flowmeter
with a valve and hose barb on the branch that I use for
clean compressed air instead of air-in-a-can. It'll work
just fine.

Ned Simmons

Dave Lyon December 1st 05 06:35 PM

flowmeter plumbing - will this work?
 

"Grant Erwin" wrote in message
...
I get tired of asking these "will this work" questions but where I live

I'd have
to drive 40 miles to ask this question of a knowledgeable local source.

Anyway,
I have a surplus regulator which I've used for some time on a CO2 tank

(plumbed
in via an adapter) but which has a connector which threads correctly to

e.g. an
argon tank. It is a pressure regulator, though, not a flowmeter, and I

want to
use this in GMAW. So I got an Airco flowmeter, removed it's weird POL-like
connector, bushed down the 1/4NPT to 1/8NPTF and put a 2½" 1/8" nipple,

and just
threaded that into the flowmeter:
http://www.tinyisland.com/images/temp/flowmeter.jpg

I have never seen a flowmeter cobbled onto the end of a regulator like

this. I'm
almost 100% ignorant in this area. Will this work correctly for me? There

are
two knobs, one sets the pressure on the regulator, the other on the

flowmeter
must be a needle valve, right? So I'd set the regulator to 30 psi on the

gauge
and then adjust the knob on the flowmeter to get my desired cubic feet per

hour
of argon?

Grant Erwin
Kirkland, Washington



You're flow meter is after the regulator, right? I think that should work.

Be careful what you put in line before the regulator. Standard fittings
aren't designed for 2200 psi.



Wayne Cook December 1st 05 07:03 PM

flowmeter plumbing - will this work?
 
On Thu, 01 Dec 2005 10:16:50 -0800, Grant Erwin
wrote:

I get tired of asking these "will this work" questions but where I live I'd have
to drive 40 miles to ask this question of a knowledgeable local source. Anyway,
I have a surplus regulator which I've used for some time on a CO2 tank (plumbed
in via an adapter) but which has a connector which threads correctly to e.g. an
argon tank. It is a pressure regulator, though, not a flowmeter, and I want to
use this in GMAW. So I got an Airco flowmeter, removed it's weird POL-like
connector, bushed down the 1/4NPT to 1/8NPTF and put a 2½" 1/8" nipple, and just
threaded that into the flowmeter:
http://www.tinyisland.com/images/temp/flowmeter.jpg

I have never seen a flowmeter cobbled onto the end of a regulator like this. I'm
almost 100% ignorant in this area. Will this work correctly for me? There are
two knobs, one sets the pressure on the regulator, the other on the flowmeter
must be a needle valve, right? So I'd set the regulator to 30 psi on the gauge
and then adjust the knob on the flowmeter to get my desired cubic feet per hour
of argon?


The only problem is knowing what pressure to set the regulator. You
need to know what pressure the flow meter is calibrated for.

Wayne Cook
Shamrock, TX
http://members.dslextreme.com/users/waynecook/index.htm

[email protected] December 1st 05 07:22 PM

flowmeter plumbing - will this work?
 
What pressure is your flowmeter calibrated for? The flowmeter is
operating at the output pressure of your regulator because the needle
valve is on the outlet of the meter and if this is high your actual gas
consumption will be higher than the flowmeter would seem to indicate.
It's sort of like having to know your voltage as well as amps to
calculate wattage.
Possibly the flowmeter manufacturer could furnish this info.
Engineman

Grant Erwin wrote:
I get tired of asking these "will this work" questions but where I live I'd have
to drive 40 miles to ask this question of a knowledgeable local source. Anyway,
I have a surplus regulator which I've used for some time on a CO2 tank (plumbed
in via an adapter) but which has a connector which threads correctly to e..g. an
argon tank. It is a pressure regulator, though, not a flowmeter, and I want to
use this in GMAW. So I got an Airco flowmeter, removed it's weird POL-like
connector, bushed down the 1/4NPT to 1/8NPTF and put a 2½" 1/8" nipple,and just
threaded that into the flowmeter:
http://www.tinyisland.com/images/temp/flowmeter.jpg

I have never seen a flowmeter cobbled onto the end of a regulator like this. I'm
almost 100% ignorant in this area. Will this work correctly for me? Thereare
two knobs, one sets the pressure on the regulator, the other on the flowmeter
must be a needle valve, right? So I'd set the regulator to 30 psi on the gauge
and then adjust the knob on the flowmeter to get my desired cubic feet per hour
of argon?

Grant Erwin
Kirkland, Washington



Grant Erwin December 1st 05 09:03 PM

flowmeter plumbing - will this work?
 
wrote:

What pressure is your flowmeter calibrated for? The flowmeter is
operating at the output pressure of your regulator because the needle
valve is on the outlet of the meter and if this is high your actual gas
consumption will be higher than the flowmeter would seem to indicate.
It's sort of like having to know your voltage as well as amps to
calculate wattage.
Possibly the flowmeter manufacturer could furnish this info.
Engineman


It's an Airco flowmeter, it's printed right on the scale, calibrated at 30 psig.
I should have written that earlier, my bad.

GWE

Grant Erwin wrote:

I get tired of asking these "will this work" questions but where I live I'd have
to drive 40 miles to ask this question of a knowledgeable local source. Anyway,
I have a surplus regulator which I've used for some time on a CO2 tank (plumbed
in via an adapter) but which has a connector which threads correctly to e.g. an
argon tank. It is a pressure regulator, though, not a flowmeter, and I want to
use this in GMAW. So I got an Airco flowmeter, removed it's weird POL-like
connector, bushed down the 1/4NPT to 1/8NPTF and put a 2½" 1/8" nipple, and just
threaded that into the flowmeter:
http://www.tinyisland.com/images/temp/flowmeter.jpg

I have never seen a flowmeter cobbled onto the end of a regulator like this. I'm
almost 100% ignorant in this area. Will this work correctly for me? There are
two knobs, one sets the pressure on the regulator, the other on the flowmeter
must be a needle valve, right? So I'd set the regulator to 30 psi on the gauge
and then adjust the knob on the flowmeter to get my desired cubic feet per hour
of argon?

Grant Erwin
Kirkland, Washington




Tom Gardner December 2nd 05 12:52 AM

flowmeter plumbing - will this work?
 
STOP!!! For GOD'S sake, don't put it under pressure...it will rent a hole
in the fabric of the Universe and obliterate EVERYTHING!!! You must destroy
this vile device at once!!!



"Grant Erwin" wrote in message
...
I get tired of asking these "will this work" questions but where I live I'd
have to drive 40 miles to ask this question of a knowledgeable local
source. Anyway, I have a surplus regulator which I've used for some time on
a CO2 tank (plumbed in via an adapter) but which has a connector which
threads correctly to e.g. an argon tank. It is a pressure regulator,
though, not a flowmeter, and I want to use this in GMAW. So I got an Airco
flowmeter, removed it's weird POL-like connector, bushed down the 1/4NPT to
1/8NPTF and put a 2½" 1/8" nipple, and just threaded that into the
flowmeter:
http://www.tinyisland.com/images/temp/flowmeter.jpg

I have never seen a flowmeter cobbled onto the end of a regulator like
this. I'm almost 100% ignorant in this area. Will this work correctly for
me? There are two knobs, one sets the pressure on the regulator, the other
on the flowmeter must be a needle valve, right? So I'd set the regulator
to 30 psi on the gauge and then adjust the knob on the flowmeter to get my
desired cubic feet per hour of argon?

Grant Erwin
Kirkland, Washington




Grant Erwin December 2nd 05 12:57 AM

flowmeter plumbing - will this work?
 
Tom Gardner wrote:
STOP!!! For GOD'S sake, don't put it under pressure...it will rent a hole
in the fabric of the Universe and obliterate EVERYTHING!!! You must destroy
this vile device at once!!!


Maybe I should send it off to someone in Ohio?

GWE

"Grant Erwin" wrote in message
...

I get tired of asking these "will this work" questions but where I live I'd
have to drive 40 miles to ask this question of a knowledgeable local
source. Anyway, I have a surplus regulator which I've used for some time on
a CO2 tank (plumbed in via an adapter) but which has a connector which
threads correctly to e.g. an argon tank. It is a pressure regulator,
though, not a flowmeter, and I want to use this in GMAW. So I got an Airco
flowmeter, removed it's weird POL-like connector, bushed down the 1/4NPT to
1/8NPTF and put a 2½" 1/8" nipple, and just threaded that into the
flowmeter:
http://www.tinyisland.com/images/temp/flowmeter.jpg

I have never seen a flowmeter cobbled onto the end of a regulator like
this. I'm almost 100% ignorant in this area. Will this work correctly for
me? There are two knobs, one sets the pressure on the regulator, the other
on the flowmeter must be a needle valve, right? So I'd set the regulator
to 30 psi on the gauge and then adjust the knob on the flowmeter to get my
desired cubic feet per hour of argon?

Grant Erwin
Kirkland, Washington





Don Foreman December 2nd 05 04:35 AM

flowmeter plumbing - will this work?
 
On Thu, 01 Dec 2005 10:16:50 -0800, Grant Erwin
wrote:

I get tired of asking these "will this work" questions but where I live I'd have
to drive 40 miles to ask this question of a knowledgeable local source. Anyway,
I have a surplus regulator which I've used for some time on a CO2 tank (plumbed
in via an adapter) but which has a connector which threads correctly to e.g. an
argon tank. It is a pressure regulator, though, not a flowmeter, and I want to
use this in GMAW. So I got an Airco flowmeter, removed it's weird POL-like
connector, bushed down the 1/4NPT to 1/8NPTF and put a 2½" 1/8" nipple, and just
threaded that into the flowmeter:
http://www.tinyisland.com/images/temp/flowmeter.jpg

I have never seen a flowmeter cobbled onto the end of a regulator like this. I'm
almost 100% ignorant in this area. Will this work correctly for me? There are
two knobs, one sets the pressure on the regulator, the other on the flowmeter
must be a needle valve, right? So I'd set the regulator to 30 psi on the gauge
and then adjust the knob on the flowmeter to get my desired cubic feet per hour
of argon?

Grant Erwin
Kirkland, Washington


That's how mine is set up.