Any issues with installing an electric furnace on it's side?
Hello all,
I have a 220V electric furnace (came from a small apartment) that I use in my garage, but it's taking up floor space. I have a plenum mounted where the A-coil normally resides with registers in it. I wan't to get it off the floor and place it on a shelf. Once up there, I'm going to run some ducting along the length of the same wall with a few registers in it. I'm sure everything else will be fine except for the blower. I guess it will be harder on the bearings having to now deal with a "side" load. I will have access to the front panel and the return will be facing the ground, so servicing isn't an issue. Should I try reconfiguring the motor so that it is horizontal or leave it as is? |
#2
|
|||
|
|||
You need to contact the manufacturer for any required modifications. Some
you can some you can't. -- Bob Pietrangelo www.comfort-solution.biz On Time or Your Service Call is FREE Preventive Maintenance Specialist "427Cobraman" wrote in message oups.com... Hello all, I have a 220V electric furnace (came from a small apartment) that I use in my garage, but it's taking up floor space. I have a plenum mounted where the A-coil normally resides with registers in it. I wan't to get it off the floor and place it on a shelf. Once up there, I'm going to run some ducting along the length of the same wall with a few registers in it. I'm sure everything else will be fine except for the blower. I guess it will be harder on the bearings having to now deal with a "side" load. I will have access to the front panel and the return will be facing the ground, so servicing isn't an issue. Should I try reconfiguring the motor so that it is horizontal or leave it as is? |
#3
|
|||
|
|||
"427Cobraman" wrote in message oups.com... Hello all, I have a 220V electric furnace (came from a small apartment) that I use in my garage, but it's taking up floor space. I have a plenum mounted where the A-coil normally resides with registers in it. I wan't to get it off the floor and place it on a shelf. Once up there, I'm going to run some ducting along the length of the same wall with a few registers in it. I'm sure everything else will be fine except for the blower. I guess it will be harder on the bearings having to now deal with a "side" load. I will have access to the front panel and the return will be facing the ground, so servicing isn't an issue. Should I try reconfiguring the motor so that it is horizontal or leave it as is? This is Turtle. A Electric furnace can be run in any possion if it does not have a evaperator coil in the air handler. As you say the evaperator coil is in the duct work down stream from the air handler so stand the air handler up side down if you like. The Possion of the air handler is only dictated by the water drains of the evaperator coil. TURTLE |
#4
|
|||
|
|||
Turtle,
I am using it for heating only, so no coil. Thanks for the advice! Alex TURTLE wrote: "427Cobraman" wrote in message oups.com... Hello all, I have a 220V electric furnace (came from a small apartment) that I use in my garage, but it's taking up floor space. I have a plenum mounted where the A-coil normally resides with registers in it. I wan't to get it off the floor and place it on a shelf. Once up there, I'm going to run some ducting along the length of the same wall with a few registers in it. I'm sure everything else will be fine except for the blower. I guess it will be harder on the bearings having to now deal with a "side" load. I will have access to the front panel and the return will be facing the ground, so servicing isn't an issue. Should I try reconfiguring the motor so that it is horizontal or leave it as is? This is Turtle. A Electric furnace can be run in any possion if it does not have a evaperator coil in the air handler. As you say the evaperator coil is in the duct work down stream from the air handler so stand the air handler up side down if you like. The Possion of the air handler is only dictated by the water drains of the evaperator coil. TURTLE |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Replacing gas furnace (was New Gas Furnace Time) | Home Ownership | |||
Need help with RUUD electric furnace | Home Repair | |||
Electric furnace fuse problem | Home Repair | |||
electric furnace (turtle??) | Home Repair | |||
Cutting floor tiles: Electric or Hand Operated cutter? | UK diy |